Viper 4 (ROS) Initial Set-Up: Injection Settings, Setup, and Definitions
65
VIPER 4 (ROS) INITIAL SET-UP
2. Select the Pressure 1 Cal value and enter a value of zero to calibrate for ambient conditions.
3. Retighten the outlet valve cartridge before resuming normal operations.
Pressure Cal 2.
Not used.
NOTE:
To monitor carrier or boom pressure, a pressure transducer may be installed and connected to the
carrier product control channel.
SECTION SETTINGS TAB
To access the Section Settings tab:
1. Touch the Edit icon in the Machine Panel to view the Machine Devices.
2. Locate and select the Product Control button.
3. Touch the Section Settings tab.
4. Touch the product indicators along the left of the prompt to select the control channel to which the pump is
assigned.
5. The section assignments for the injection system should be matched to the carrier product assignments to
accurately map and control rate of the injected products.
Refer to the ROS Product Control Calibration and Operation Manual for additional assistance with section
assignments settings.
ALARM SETTINGS TAB
To access the Alarm Settings tab:
1. Touch the Edit icon in the Machine Panel to view the Machine Devices.
2. Locate and select the Product Control button.
3. Touch the Alarm Settings tab.
4. Touch the product indicators along the left of the prompt to select the control channel to which the pump is
assigned. Depending upon the injection system connected, the following settings may be available:
Low Tank Volume (Optional).
Enter the volume at which to alert the operator to a low tank condition during
field operations. This feature requires the operator to enter an initial tank level on the product settings tab
when refilling tanks to allow ROS to calculate the tank level during the operation.
Low Flow Limit.
Enter 5 oz/minute (optional). The low flow limit value sets the minimum volume per minute
acceptable during application of a product. If the monitored flow rate drops below the low limit, ROS will
override the injection pump to maintain the entered low limit and display a flow alarm to alert the operator.
NOTE:
ROS will automatically adjust the low flow limit value for active sections.
Edit
Product
Control
Section
Settings
Edit
Product
Control
Alarm
Settings
Содержание Sidekick Pro
Страница 12: ...CHAPTER 2 10 CAN Sidekick Pro Injection for Case IH 3 4XXX Installation and Operation Manual ...
Страница 84: ...CHAPTER 7 82 CAN Sidekick Pro Injection for Case IH 3 4XXX Installation and Operation Manual ...
Страница 88: ...CHAPTER 8 86 CAN Sidekick Pro Injection for Case IH 3 4XXX Installation and Operation Manual ...
Страница 89: ...CHAPTER 9 System Diagrams Electrical 87 CHAPTER9SYSTEM DIAGRAMS ELECTRICAL Drawings start on next page ...
Страница 91: ...System Diagrams Electrical 89 SYSTEM DIAGRAMS FIGURE 2 Single Pump System Diagram ...
Страница 93: ...System Diagrams Electrical 91 SYSTEM DIAGRAMS PLUMBING FIGURE 4 Dual Pump Injection Plumbing ...
Страница 96: ...Index 94 CAN Sidekick Pro Injection for Case IH 3 4XXX Installation and Operation Manual ...