CHAPTER 3
SYSTEM CALIBRATION
INITIAL START UP AND CALIBRATION WIZARD
The calibration wizard must be completed the first time that the system is powered up on the ISOBUS network or
if the default system settings are reset. The calibration wizard allows the operator to quickly configure the Rate
Control Module (RCM) - Sprayer ECU and Hawkeye® 2 NCV2s if detected.
Review the following sections for assistance with completing the calibration wizard for the Hawkeye® 2 control
system.
NOTE:
Refer to the UT Operation Manual for other necessary setup or calibration required before operating
the
RCM - Sprayer
control system or features.
TRANSFER UNIVERSAL TERMINALS
The Transfer UT softkey will be displayed if more than one UT is detected on the ISOBUS. Use
this button to switch the RCM - Sprayer working set menu to an alternate UT at any time.
If the working set is not available on the desired UT, check the other displays and use the
Transfer UT softkey to transfer the RCM - Sprayer working set.
By default, the working set will load to the first UT detected by the ISOBUS. When using
the Transfer UT softkey, the working set will automatically load to the last UT selected
unless the system requires calibration or the last UT cannot be detected within two
minutes.
CALIBRATION WIZARD
The following steps may help with completing the initial setup of the RCM - Sprayer
control system
:
1. Turn the UT power on and allow the display to initiate the ISOBUS system.
NOTE:
If properly connected and powered, the UT will automatically detect the Raven RCM - Sprayer ECU.
If the RCM - Sprayer ECU is not detected by the display terminal, troubleshoot the ECU and restart the
system. Refer to Chapter 9,
, for assistance with connection issues or contact a local
Raven dealer for additional troubleshooting assistance.
2. Once the RCM - Sprayer ECU is detected, the RCM - Sprayer Menu button will display in the UT Menu.
3. Touch the Menu button to access the control system user interface.
4. The first time that the system is started on the UT, or if the default settings have been reset, the first calibration
wizard prompt will be displayed.
Transfer UT
RCM - Sprayer Menu
Содержание RCM-Sprayer Hawkeye 2
Страница 6: ...TABLE OF CONTENTS iv RCM Sprayer and Hawkeye 2 Calibration and Operation Manual ...
Страница 10: ...CHAPTER 1 viii RCM Sprayer and Hawkeye 2 Calibration and Operation Manual ...
Страница 20: ...CHAPTER 2 10 RCM Sprayer and Hawkeye 2 Calibration and Operation Manual ...
Страница 28: ...CHAPTER 3 18 RCM Sprayer and Hawkeye 2 Calibration and Operation Manual ...
Страница 52: ...CHAPTER 5 42 RCM Sprayer and Hawkeye 2 Calibration and Operation Manual ...
Страница 60: ...CHAPTER 6 50 RCM Sprayer and Hawkeye 2 Calibration and Operation Manual ...
Страница 66: ...CHAPTER 8 56 RCM Sprayer and Hawkeye 2 Calibration and Operation Manual ...
Страница 90: ...APPENDIX A 80 RCM Sprayer and Hawkeye 2 Calibration and Operation Manual ...
Страница 94: ...APPENDIX B 84 RCM Sprayer and Hawkeye 2 Calibration and Operation Manual ...
Страница 107: ... Boom Harness Connector Maintenance 97 FIGURE 3 Applying Corrosion Inhibitor NCV2 Connector Corrosion Inhibitor Applied ...
Страница 108: ...APPENDIX D 98 RCM Sprayer and Hawkeye 2 Calibration and Operation Manual ...
Страница 120: ...APPENDIX F 110 RCM Sprayer and Hawkeye 2 Calibration and Operation Manual ...