CHAPTER 2
6
RCM - Sprayer and Hawkeye® 2 Calibration and Operation Manual
RCM - SPRAYER FEATURES
OPERATION MODES
The RCM - Sprayer with Hawkeye® 2 control system can be configured in several different modes to fit the
application.
TABLE 1.
Operation Modes and Compatible Features
Bypass (Conventional) Mode.
The RCM - Sprayer with Hawkeye® 2 mode will control to a target flow, but the
nozzle control valves on the system are disabled. A secondary flow outlet must be made available at each tip.
NOTE:
If NCV2s are not detected, the RCM - Sprayer system will automatically configure in Bypass mode.
Bypass mode may also be selected to revert a system with Hawkeye® 2 NCVs to conventional spray
control.
Only select bypass mode if the nozzle bodies on the implement are set to bypass the
Hawkeye® 2
NCVs during operation.
Standard Mode.
The RCM - Sprayer with Hawkeye® 2 mode will control to a target flow rate and maintain a
constant target pressure.
Variable Pressure (VP) Mode.
This RCM - Sprayer with Hawkeye® 2 mode will control to a target flow rate and
target NCV2 duty cycle by varying the pressure range. This is useful for scenarios where maintaining a constant
target pressure is not a priority such as liquid fertilizer application or where droplet size can be maintained over
a wide pressure range.
High Flow Mode.
This RCM - Sprayer with Hawkeye® 2 mode allows both a conventional nozzle and a
Hawkeye® 2 NCV to run simultaneously to achieve higher flow rates.
On/Off Mode.
The RCM - Sprayer with Hawkeye® 2 System will hold the NCV2s 100% open during application or
fully closed when not applying. This mode can be used with air induction tips and stream bars.
Modes of Operation
Conventional
/Bypass
Standard
Variable
Pressure (VP)
High
Flow
On/Off
Comp
ati
b
le
Features
Direct
Injection
Yes
Yes
Yes
Yes
Yes
Wireless
Diagnostics
Yes
Yes
Yes
Yes
Yes
Flow Control
Yes
Yes
Yes
Yes
Yes
Pressure
Control
No
Yes
No
Yes
No
Turn
Compensation
No
Yes
Yes
Yes
No
Virtual
Sections
No
Yes
Yes
No
Yes
Hawkeye HD
Individual
Nozzle Control
No
Yes
Yes
No
Yes
Содержание RCM-Sprayer Hawkeye 2
Страница 6: ...TABLE OF CONTENTS iv RCM Sprayer and Hawkeye 2 Calibration and Operation Manual ...
Страница 10: ...CHAPTER 1 viii RCM Sprayer and Hawkeye 2 Calibration and Operation Manual ...
Страница 20: ...CHAPTER 2 10 RCM Sprayer and Hawkeye 2 Calibration and Operation Manual ...
Страница 28: ...CHAPTER 3 18 RCM Sprayer and Hawkeye 2 Calibration and Operation Manual ...
Страница 52: ...CHAPTER 5 42 RCM Sprayer and Hawkeye 2 Calibration and Operation Manual ...
Страница 60: ...CHAPTER 6 50 RCM Sprayer and Hawkeye 2 Calibration and Operation Manual ...
Страница 66: ...CHAPTER 8 56 RCM Sprayer and Hawkeye 2 Calibration and Operation Manual ...
Страница 90: ...APPENDIX A 80 RCM Sprayer and Hawkeye 2 Calibration and Operation Manual ...
Страница 94: ...APPENDIX B 84 RCM Sprayer and Hawkeye 2 Calibration and Operation Manual ...
Страница 107: ... Boom Harness Connector Maintenance 97 FIGURE 3 Applying Corrosion Inhibitor NCV2 Connector Corrosion Inhibitor Applied ...
Страница 108: ...APPENDIX D 98 RCM Sprayer and Hawkeye 2 Calibration and Operation Manual ...
Страница 120: ...APPENDIX F 110 RCM Sprayer and Hawkeye 2 Calibration and Operation Manual ...