Manual No. 016-3001-015 Rev. C
257
PWM Control Valve Tuning
The Viper Pro field computer provides three methods for fine tuning a PWM or PWM close valve used for
controlling product application:
PWM Manual Calibration
The operator may enter the known values for the following PWM valve calibration settings within the Product
Control Settings area:
Note:
The PWM valve will not be operated during manual calibration. It is recommended to verify that
any changes to these settings will have the desired affect before controlling product application.
Refer to the Node Control Settings Screen (Page 2) section on page 157 for more information on
the min pw, max pw values and the Node Control Settings Screen (Page 3) section on page 159
for details on the standby pressure, preset pw and pw freq values.
PWM Calibration Assistance
The calibration assistant allows the operator to manually increase or decrease the PWM output using on-
screen controls and set the PWM minimum, maximum, frequency and preset values based upon observed
operation.
Note:
It is recommended to perform the calibration process with water in liquid tanks or while performing
a catch test with a dry or granular application system.
To use the calibration assistant mode, toggle the vehicle master switch and at least one section to the on
position. To stop the PWM output at any time during the calibration process, toggle the vehicle master switch to
the off position.
Note:
Refer to the Node Control Settings Screen (Page 2) section on page 157 for more information on
the min pw, max pw values and the Node Control Settings Screen (Page 3) section on page 159
for details on the standby pressure, preset pw and pw freq values configured using the calibration
assistant.
1.
Touch within the Product Control Settings area on the CAN Controller Status screen. The first Node 1
Settings screen will display.
•
Min PW
(Minimum Pulse Width)
•
Standby Pressure
•
PW Freq
(Pulse Width Frequency)
•
(Max PW)
Maximum Pulse Width
•
Pre Set PW
(Preset Pulse Width)
WARNING
The PWM valve output will increase and
decrease as the up and down arrows are
selected. Keep any bystanders away from
areas where product may be expelled and
moving components when performing the
calibration process.
Содержание OmniSeed Viper Pro
Страница 1: ...Viper Pro Software Version 3 10 OmniSeed Calibration Operation Manual ...
Страница 10: ...Table of Contents viii OmniSeed Viper Pro Calibration Operation Manual ...
Страница 98: ...Chapter 4 86 OmniSeed Viper Pro Installation Operation Manual ...
Страница 150: ...Chapter 6 138 OmniSeed Viper Pro Installation Operation Manual ...
Страница 222: ...Chapter 10 210 OmniSeed Viper Pro Installation Operation Manual ...
Страница 240: ...Chapter 11 228 OmniSeed Viper Pro Installation Operation Manual ...
Страница 250: ...Appendix A 238 OmniSeed Viper Pro Installation Operation Manual FIGURE 1 OmniSeed System Diagram 3 Bin D N 054 5010 003 ...
Страница 251: ...Manual No 016 3001 015 Rev C 239 FIGURE 2 OmniSeed System Diagram 3 Bin D N 054 3001 026 ...
Страница 255: ...Manual No 016 3001 015 Rev C 243 FIGURE 6 Seed Blockage Sensor Cabling More than 60 Sensors D N 054 5002 002 ...
Страница 256: ...Appendix A 244 OmniSeed Viper Pro Installation Operation Manual ...
Страница 284: ...Appendix D 272 OmniSeed Viper Pro Installation Operation Manual ...
Страница 292: ...Appendix G 280 OmniSeed Viper Pro Installation Operation Manual ...
Страница 300: ...Appendix H 288 OmniSeed Viper Pro Installation Operation Manual ...
Страница 304: ...Index 292 OmniSeed Viper Pro Calibration Operation Manual ...
Страница 307: ......