OmniSeed Section Control
Section Control Apply/No-Apply Maps
A section control apply/no-apply map may be created on the Viper Pro before an actual job or product
application using the scouting function or the map may be created during the application. The first step in
creating a section control apply/no-apply map is to define the apply and no-apply zones within a field. These
zones are created in the same method as boundary fields.
Note:
The apply and no-apply selections will only be available while creating a map.
How to Create a Zone Map
1.
Start a new job.
2.
Touch the
Scout
tab.
3.
Select
Record
, then
Zone
. The Record Field Feature screen displays.
4.
Select
Apply
or
No-Apply
.
Note:
Only one zone type can be created at a time.
5.
Select an offset shift for the boundary that is in relationship to one-half the implement width.
6.
Touch
OK
. Viper draws the boundary line on the Scout map as the machine drive travels along the zone
boundary.
7.
To close the boundary, touch
Finish
.
Note:
Apply/no-apply zones do not have the auto close feature. Touch the Finish button and select the
Zone to finish at the end of the boundary.
8.
To define additional apply/no-apply zones, repeat step 3 through 7 for each apply or no-apply boundary to
define.
Содержание OmniSeed Viper Pro
Страница 1: ...Viper Pro Software Version 3 10 OmniSeed Calibration Operation Manual ...
Страница 10: ...Table of Contents viii OmniSeed Viper Pro Calibration Operation Manual ...
Страница 98: ...Chapter 4 86 OmniSeed Viper Pro Installation Operation Manual ...
Страница 150: ...Chapter 6 138 OmniSeed Viper Pro Installation Operation Manual ...
Страница 222: ...Chapter 10 210 OmniSeed Viper Pro Installation Operation Manual ...
Страница 240: ...Chapter 11 228 OmniSeed Viper Pro Installation Operation Manual ...
Страница 250: ...Appendix A 238 OmniSeed Viper Pro Installation Operation Manual FIGURE 1 OmniSeed System Diagram 3 Bin D N 054 5010 003 ...
Страница 251: ...Manual No 016 3001 015 Rev C 239 FIGURE 2 OmniSeed System Diagram 3 Bin D N 054 3001 026 ...
Страница 255: ...Manual No 016 3001 015 Rev C 243 FIGURE 6 Seed Blockage Sensor Cabling More than 60 Sensors D N 054 5002 002 ...
Страница 256: ...Appendix A 244 OmniSeed Viper Pro Installation Operation Manual ...
Страница 284: ...Appendix D 272 OmniSeed Viper Pro Installation Operation Manual ...
Страница 292: ...Appendix G 280 OmniSeed Viper Pro Installation Operation Manual ...
Страница 300: ...Appendix H 288 OmniSeed Viper Pro Installation Operation Manual ...
Страница 304: ...Index 292 OmniSeed Viper Pro Calibration Operation Manual ...
Страница 307: ......