Manual No. 016-0171-148
179
Calculating the Calibration Values
Meter Cal
The flow meter calibration number can be found on the tag attached to each flow meter. Copy the information
from the tag for future reference as the tags may fade or be lost during equipment operation.
Valve Cal
To ensure that the proper amount of product is being applied, the valve cal must be programmed for the type of
control valve(s) connected to the control system. The field computer uses the valve calibration number to
adjust the response time of the control valve motor to changes in the vehicle speed.
The following control valve calibration numbers are recommended for the valves listed:
Each digit in the calibration number corresponds to a specific function of the valve. The following functions
apply to the digits in the valve calibration number:
Valve Backlash Digit
This value controls the time of the first correction pulse after detecting a change in correction direction. The
values range from 1 to 9, where 1 is for a short pulse and 9 is for a long pulse.
Note:
The backlash digit is not used with a fast, fast close, PWM, PWM close or standard motor control
valve.
Valve Speed Digit
This value controls the response time of the control valve motor. If the valve speed setting is too fast, the valve
will over correct and the system can start to oscillate. The following valves have specific values:
•
Standard Control Valve: This valve has a range of values from 1 to 9, with 1 being slow and 9 being fast.
•
Fast and Fast Close Control Valve: These valves have a range of values from 0 to 9, with 0 for fast and 9 for
slow.
Note:
The speed digit is not used with a PWM or PWM close valve.
Brake Point Digit
The Brake Point digit sets the percent away from the target rate at which the control valve starts to turn at a
slower rate so that it does not overshoot the target rate. The values range from 0 to 9, where 0 is a 5% rate, 1
is a 10% rate and 90 is a 90% rate.
Control Valve Type
Valve Cal
Standard (C-SD)
2123
Fast (C-F) or Fast Close (C-FC)
743
PWM (C-P) or PWM Close (C-PC)
43
Dead Band Digit
Break Point Digit
Valve Backlash Digit
Valve Speed Digit
Содержание Envizio Pro
Страница 1: ...Software Version 3 2 Envizio Pro Envizio Pro II Installation Operation Manual...
Страница 36: ...Chapter 3 26 Envizio Pro and Envizio Pro II Installation and Operation Manual...
Страница 148: ...Chapter 7 138 Envizio Pro and Envizio Pro II Installation and Operation Manual...
Страница 158: ...Chapter 8 148 Envizio Pro and Envizio Pro II Installation and Operation Manual...
Страница 174: ...Chapter 9 164 Envizio Pro and Envizio Pro II Installation and Operation Manual...
Страница 178: ...Chapter 10 168 Envizio Pro and Envizio Pro II Installation and Operation Manual...
Страница 184: ...Chapter 11 174 Envizio Pro and Envizio Pro II Installation and Operation Manual...
Страница 210: ...Appendix D 200 Envizio Pro and Envizio Pro II Installation and Operation Manual...
Страница 230: ...Index 220 Envizio Pro Envizio Pro II Installation Operation Manual...