CHAPTER 4
26
RCM - Sprayer and AIM Command FLEX™ II Calibration and Operation Manual
Select Tip and Tip Name.
Use the drop-down list to:
a. Set up a new spray tip that will be used with the system.
b. Select a spray tip previously set up.
Enter a name (up to 12 characters) for the tips to allow the operator to quickly select the appropriate spray tips
for the field application.
NOTE:
The tip size profile will display as “---” if the NCV or bypass tip size is not editable based upon the
selected NCV control mode.
Press the “X” button to delete the selected tip and to remove it from the Select Tip and Tip Name
drop-down list.
NCV Tip Size.
Select the size of the spray tips installed on the AIM Command FLEX™ II NCVs.
Droplet Size.
Enter the published droplet size information available from the tip manufacturer for the tip size and
series.
Minimum/Maximum Pressures.
Enter the pressure range (minimum and maximum) for the spray tips installed to
help maintain the desired droplet sizing.
NOTE:
When entering pressure ranges for different droplet size classifications, ensure that the values entered
are within the overall minimum and maximum spray pressure range set in the Pressure Setup Menu.
TEST SPEED
The Test Speed feature allows the operator to enter a simulated speed for the system and allows the operator to
check and verify system operation and functionality while the equipment remains stationary.
To enter a test speed:
NOTE:
A test speed may also be entered via the Speed Readout on the Home page. Refer to the
section on page 32 for assistance with customizing the Home tab displays.
1. Open the UT Menu and select the RCM - Sprayer Menu button.
2. Select the Tools Menu softkey along the right side of the display.
3. Select the Applicator Setup tab along the top of the display.
4. Select the Test Speed button. The Test Speed page will be displayed.
5. Either enter the desired simulated speed or select the Resume Last Speed button to set the speed for testing
system operation.
NOTE:
Enter a test speed that is within the acceptable speed range for the system as setup. Entering a test
speed above or below the recommended speed range may result in alarms or product shut down.
RCM - Sprayer Menu
Tools Menu
Applicator
Setup
UT Menu
Test Speed
Содержание Command FLEX II
Страница 20: ...CHAPTER 2 10 RCM Sprayer and AIM Command FLEX II Calibration and Operation Manual ...
Страница 30: ...CHAPTER 3 20 RCM Sprayer and AIM Command FLEX II Calibration and Operation Manual ...
Страница 54: ...CHAPTER 4 44 RCM Sprayer and AIM Command FLEX II Calibration and Operation Manual ...
Страница 58: ...CHAPTER 5 48 RCM Sprayer and AIM Command FLEX II Calibration and Operation Manual ...
Страница 68: ...CHAPTER 6 58 RCM Sprayer and AIM Command FLEX II Calibration and Operation Manual ...
Страница 118: ...APPENDIX A 108 RCM Sprayer and AIM Command FLEX II Calibration and Operation Manual ...
Страница 122: ...APPENDIX B 112 RCM Sprayer and AIM Command FLEX II Calibration and Operation Manual ...
Страница 134: ...APPENDIX D 124 RCM Sprayer and AIM Command FLEX II Calibration and Operation Manual ...
Страница 142: ...APPENDIX F 132 RCM Sprayer and AIM Command FLEX II Calibration and Operation Manual ...