4
System Setup: Applicator Setup Tab
23
SYSTEM SETUP
Wired Signal Driver.
Displays the “wired as” signal driver that controls the section.
Switch Number.
The number of the switch to which the section is assigned.
Tip Spacing.
The value and units set for nozzle body spacing is displayed in this field.
Page 2 of the Section Setup Summary displays the Section Auto-Operation Times. These values set the time
each section will run for automated priming and recirculation functions. The maximum auto-operation time is
180 seconds.
FENCE ROW SETTINGS
To review the current section setup:
1. Open the UT Menu and select the RCM - Sprayer Menu button.
2. Select the Tools Menu softkey along the right side of the display.
3. Select the Applicator Setup tab along the top of the display.
4. Select the Section Setup Summary button. The Section Summary page will be displayed.
5. Select the Fence Row Settings icon. The following features and options will be displayed:
Enable On-Screen Fence Row Buttons.
Select the Enable On-Screen Fence Row Buttons to allow the operator to
toggle fence rows on and off via buttons displayed on the UT screen. When this option is disabled, fence rows
must be activated via another switch or button on the machine.
NOTE:
This feature may only be changed in the profile wizard.
Map Fence Rows as Sections.
Select the Map Fence Rows as Sections to show additional applied area on the
coverage map when fence rows are activated. When left disabled, fence row area will not be mapped or
calculated in the coverage area when fence rows are activated.
NOTE:
This feature may only be changed in the profile wizard.
Fence Row Width.
Enter the width covered when one of the fence rows is activated and the spray boom is at the
target height.
NOTE:
This value may only be edited in the profile wizard.
Fence Row Tip Size.
If a spray tip is equipped on the fence row nozzles, select the tip size from the drop down
list.
Fence Row Switch Assignments.
If the On-Screen Fence Row Buttons is not used, select the switch number to
which the left and right fence rows are assigned.
NOTE:
These options are only editable when “Fence Valve” is selected for custom boom setups.
RCM - Sprayer
Menu
Tools Menu
Applicator
Setup
UT Menu
Section Setup
Summary
Fence Row
Settings
Содержание Command FLEX II
Страница 20: ...CHAPTER 2 10 RCM Sprayer and AIM Command FLEX II Calibration and Operation Manual ...
Страница 30: ...CHAPTER 3 20 RCM Sprayer and AIM Command FLEX II Calibration and Operation Manual ...
Страница 54: ...CHAPTER 4 44 RCM Sprayer and AIM Command FLEX II Calibration and Operation Manual ...
Страница 58: ...CHAPTER 5 48 RCM Sprayer and AIM Command FLEX II Calibration and Operation Manual ...
Страница 68: ...CHAPTER 6 58 RCM Sprayer and AIM Command FLEX II Calibration and Operation Manual ...
Страница 118: ...APPENDIX A 108 RCM Sprayer and AIM Command FLEX II Calibration and Operation Manual ...
Страница 122: ...APPENDIX B 112 RCM Sprayer and AIM Command FLEX II Calibration and Operation Manual ...
Страница 134: ...APPENDIX D 124 RCM Sprayer and AIM Command FLEX II Calibration and Operation Manual ...
Страница 142: ...APPENDIX F 132 RCM Sprayer and AIM Command FLEX II Calibration and Operation Manual ...