CHAPTER 3
18
RCM - Sprayer and AIM Command FLEX™ II Calibration and Operation Manual
2. Touch the Rate Selection drop-down field and select the desired method for setting rates during field
applications.
NOTE:
This option may be changed after the initial calibration is complete. Refer to the
section on page 42, for additional assistance.
3. Enable the Display Smoothing feature to allow the system to smooth the product application rate display
during field applications. Refer to the
section on page 42 for additional information about
the Display Smoothing feature.
4. Touch the Next button to complete the initial setup and calibration of the AIM Command FLEX™ II system.
NOTE:
Additional rate setup pages may be displayed for any additional products detected on the system.
FUNCTIONAL INSPECTION
Refer to the following sections for assistance with validating that the RCM - Sprayer and AIM Command FLEX™ II
systems have been installed and calibrated properly.
SYSTEM FUNCTION
To verify that the system is functioning properly after installation:
1. Flush the main product tank and boom plumbing with clean water and verify the tank contains at least 100
gallons [379 L] of clean water.
2. Park the equipment in an area with enough space to unfold the booms and allows for visual inspection of the
spray pattern from a moderate distance (e.g. 20 ft [6.1 m]).
3. If present, toggle the AIM Command FLEX™ II nozzle control system to manual mode and set both the control
valve and NCV DC to 50%.
4. Access the manual Control Valve setting by pressing the PR1 tab on the Home screen. Access the NCV DC%
setting by pressing the pressure tab on the Home screen.
5. If necessary, open the tank sump valve.
6. If present, turn on the machine pump switch.
7. Toggle the on-screen product on/off button to engage the product pump.
8. Toggle all section switches and the master switch.
9. While maintaining a safe distance away from any spray and spray drift, visually check that all spray tips are
spraying and, if present, all nozzle control valves are pulsing with a uniform pattern. Adjacent nozzle control
valves should alternate pulsing. If adjacent NCVs are pulsing at the same time, refer to Chapter 9,
, for additional assistance.
10. On the UT, set the control valve to about 30%. For systems without NCVs, turn off the master switch and close
section valves. For systems with NCVs, set the NCV DC % (duty cycle %) to 0% to close the nozzle control valves
and maintain a safe pressure in the boom.
WARNING
Equipment will begin spraying. Avoid inhaling
spray particulate and avoid direct contact with
any agricultural chemicals. Seek immediate
medical attention if symptoms of illness occur
during, or soon after, use of agricultural
chemicals, products, or equipment.
Содержание Command FLEX II
Страница 20: ...CHAPTER 2 10 RCM Sprayer and AIM Command FLEX II Calibration and Operation Manual ...
Страница 30: ...CHAPTER 3 20 RCM Sprayer and AIM Command FLEX II Calibration and Operation Manual ...
Страница 54: ...CHAPTER 4 44 RCM Sprayer and AIM Command FLEX II Calibration and Operation Manual ...
Страница 58: ...CHAPTER 5 48 RCM Sprayer and AIM Command FLEX II Calibration and Operation Manual ...
Страница 68: ...CHAPTER 6 58 RCM Sprayer and AIM Command FLEX II Calibration and Operation Manual ...
Страница 118: ...APPENDIX A 108 RCM Sprayer and AIM Command FLEX II Calibration and Operation Manual ...
Страница 122: ...APPENDIX B 112 RCM Sprayer and AIM Command FLEX II Calibration and Operation Manual ...
Страница 134: ...APPENDIX D 124 RCM Sprayer and AIM Command FLEX II Calibration and Operation Manual ...
Страница 142: ...APPENDIX F 132 RCM Sprayer and AIM Command FLEX II Calibration and Operation Manual ...