APPENDIX B
110
RCM - Sprayer and AIM Command FLEX™ II Calibration and Operation Manual
PRODUCT CALIBRATION SETTINGS
Control Valve Settings and Tuning
section on page 27 for assistance with calibrating and tuning the
product control valve.
FLOW METER RE-CALIBRATION
1. Enter a meter cal number of 10 [38].
2. Enter a total volume of 0.
3. Switch all booms off.
4. Remove a boom hose and place it in a calibrated 5 gallon [19 liter] container.
5. Turn on the boom and master switches.
6. Pump exactly 10 gallons [38 liters].
7. The readout in total volume is the new meter cal number. This number should be within ±3% of the number
stamped of the flow meter tag.
8. Zero out the total volume.
9. Repeat the calibration procedure several times to confirm the reading accuracy.
NOTE:
For greatest precision, set the meter cal to 100 [378 liters] and pump 100 gallons [378 liters] of water.
10. To verify the flow meter calibration, fill the applicator tank with a predetermined amount of measured liquid
(e.g. 250 gallons [946.4 L]). Do not rely on the graduation numbers molded into the applicator tank. Empty the
applicator tank under normal operating conditions. If the number displayed under the total volume is different
from the predetermined amount of measured liquid by more than ±3%, complete the following calculation.
FOR EXAMPLE:
A meter cal of 720 [190], total volume of 260 [983], and a predetermined amount of measured
liquid equaling 250 [946]:
US Units:
Metric Units:
Enter a corrected meter cal of 749 [198].
11. Enter the corrected meter cal before resuming application.
CorrectedMeterCal
MeterCal TotalVolume
×
MeasuredVolume
--------------------------------------------------------------------
720
260
×
250
------------------------
748.8
=
=
=
CorrectedMeterCal
MeterCal TotalVolume
×
MeasuredVolume
--------------------------------------------------------------------
190
[
]
983
[
]
×
946
[
]
----------------------------------
197.4
=
=
=
Содержание Command FLEX II
Страница 20: ...CHAPTER 2 10 RCM Sprayer and AIM Command FLEX II Calibration and Operation Manual ...
Страница 30: ...CHAPTER 3 20 RCM Sprayer and AIM Command FLEX II Calibration and Operation Manual ...
Страница 54: ...CHAPTER 4 44 RCM Sprayer and AIM Command FLEX II Calibration and Operation Manual ...
Страница 58: ...CHAPTER 5 48 RCM Sprayer and AIM Command FLEX II Calibration and Operation Manual ...
Страница 68: ...CHAPTER 6 58 RCM Sprayer and AIM Command FLEX II Calibration and Operation Manual ...
Страница 118: ...APPENDIX A 108 RCM Sprayer and AIM Command FLEX II Calibration and Operation Manual ...
Страница 122: ...APPENDIX B 112 RCM Sprayer and AIM Command FLEX II Calibration and Operation Manual ...
Страница 134: ...APPENDIX D 124 RCM Sprayer and AIM Command FLEX II Calibration and Operation Manual ...
Страница 142: ...APPENDIX F 132 RCM Sprayer and AIM Command FLEX II Calibration and Operation Manual ...