Troubleshooting: Cable Troubleshooting
95
TROUBLESHOOTING
TROUBLESHOOTING FLOW METER CABLES
Disconnect the extension cable from the flow meter. Hold the extension cable so that the keyway is facing toward
the 12 o’clock position.
FIGURE 8. Flow Meter Extension Cable Pin Diagram (Con-X-All)
TABLE 7.
Flow Meter with Deutsch DT Connector
TABLE 8.
Flow Meter with Deutsch DTM Connector
TEST THE FLOW METER CABLE
To test the flow meter cable:
1. Open the UT Menu and select the RCM - Sprayer Menu button.
2. From the home screen, change the product Rate Control Mode to Manual.
NOTE:
Ensure the control valve output is zero.
3. Access the Tools Menu and select the Rate Setup and set the Flow Meter Calibration value to 1.
4. Change the Flow Meter Pulse/Units to 1 (not 10 pulses per unit).
Pin
Function
A
Power
B
Ground
C
Signal
Pin
Function
1
Signal
2
Ground
3
Power
Keyway
5 VDC
5 VDC
2 o’clock
Ground
10 o’clock
Power
6 o’clock
Signal
RCM - Sprayer Menu Tools Menu
UT Menu
Rate Sensor
Setup
Rate Setup
Содержание Command FLEX II
Страница 20: ...CHAPTER 2 10 RCM Sprayer and AIM Command FLEX II Calibration and Operation Manual ...
Страница 30: ...CHAPTER 3 20 RCM Sprayer and AIM Command FLEX II Calibration and Operation Manual ...
Страница 54: ...CHAPTER 4 44 RCM Sprayer and AIM Command FLEX II Calibration and Operation Manual ...
Страница 58: ...CHAPTER 5 48 RCM Sprayer and AIM Command FLEX II Calibration and Operation Manual ...
Страница 68: ...CHAPTER 6 58 RCM Sprayer and AIM Command FLEX II Calibration and Operation Manual ...
Страница 118: ...APPENDIX A 108 RCM Sprayer and AIM Command FLEX II Calibration and Operation Manual ...
Страница 122: ...APPENDIX B 112 RCM Sprayer and AIM Command FLEX II Calibration and Operation Manual ...
Страница 134: ...APPENDIX D 124 RCM Sprayer and AIM Command FLEX II Calibration and Operation Manual ...
Страница 142: ...APPENDIX F 132 RCM Sprayer and AIM Command FLEX II Calibration and Operation Manual ...