Use and maintenance manual Magnus
Pag.37
Rev.1 21/04/2021
CONNECTIONS
📌
The connections must be set up by a technician that is qualified and/or authorised by the Manufacturer.
📌
By the installer the type of cable, with relative section, to be installed in case of replacement is: H05RR-F sez.3G0,75
Connection with external air intake
The stove has been designed for hermetic installations.
To make the connection with an external air intake, proceed as follows:
step
action
1
Connect a 50 mm diameter pipe to the combustion air inlet pipe at the back of the stove.
Note: the pipe must be no more than 2 m in length.
⚠
The air vent must be installed in such a way that it can not be blocked.
Chimney connection
⚠
The chimney must be sized so as to guarantee the draught declared by the Manufacturer.
⚠
The stove must be connected to a single flue. It is forbidden to connect the stove to a flue shared with other combustion
appliances or with hood exhausts.
Electrical connection
The plug of the stove’s power cable must only be connected after the installation and assembly has been completed of the applian-
ce, and must remain accessible after installation.
To make the electrical connection, proceed as described below:
First connect the power cable to the plug on the back of the stove and then to a wall socket.
Supply power to the stove by turning the switch to position (I).
📌
When the stove is not in use, it is advisable to disconnect the power cable.
⚠
Take care that the power cord (and any other cables outside the equipment) do not come into contact with hot surfaces.
⚠
Ensure that the electrical system is grounded.
⚠
For direct connection to the mains, it is necessary to provide a device that ensures disconnection from the mains, with a
contact opening distance that allows complete disconnection under the conditions of overvoltage category III, in accordance
with installation rules
⚠
If the power supply cable is damaged, it must be replaced by the manufacturer or its technical assistance service or in any
case by a person with similar qualifications, so as to prevent any risk.
⚠
It is recommended that authorized personnel pay special attention to the electrical connections after any work on the product.
Switch
Power plug
Fuse
Содержание Magnus
Страница 1: ...USE AND MAINTENANCE MANUAL Magnus...
Страница 2: ......
Страница 26: ...Use and maintenance manual Magnus Pag 26 Rev 1 21 04 2021 Removing of the fixing brackets 1 2 3 x1 x2...
Страница 27: ...Use and maintenance manual Magnus Pag 27 Rev 1 21 04 2021 Assembly of the wheels x1 x1 1 2...
Страница 28: ...Use and maintenance manual Magnus Pag 28 Rev 1 21 04 2021 Assembly of the baffle 1 2 3 4...
Страница 71: ......