INSTALLATION MANUAL
–
RCS
Hy-Q-52
11
4.3 Mechanics: Installing the position switch holder
1.
2.
40 cm
The position switch holder and magnet
contain the following parts:
1. 1 magnet, to be installed on the carriage
plate (moving part)
2. 1 profile with 2 reed switches inside, to
be installed on the mast (fixed part)
The distance between the magnet and the
switches should be in the range of 5-20mm.
The magnet and lowest switch should face
each other when the forks are about 40cm
from the ground.
Place the magnet at a location that is free
from obstacles all the way up and down
the mast.
Degrease the area on the carriage plate
where the magnet will be mounted.
The magnet holder can be installed on the
carriage plate with the self-adhesive tape
or bolts.
This side must
face the sensors
on the mast!