background image

ProLine 5200-Li

We would like to inform you about the fact that this RAVAS product is 100% recyclable on the basis that the 

parts are processed and disposed of in the right manner.

More information can be found on our website: 

www.ravas.com

Rev. 20211118

Printing/Typographical errors and model changes reserved.

      

    

USER MANUAL

 – 

ProLine 5200-Li

1

USER MANUAL

Содержание ProLine 5200-Li

Страница 1: ...product is 100 recyclable on the basis that the parts are processed and disposed of in the right manner More information can be found on our website www ravas com Rev 20211118 Printing Typographical e...

Страница 2: ...instructions or from negligent operation or assembly even if this is not expressly stated in this instruction manual In light of our policy of continuous improvement it is possible that details of th...

Страница 3: ...8 5 8 Adding print clear memory send data 20 5 8 1 Add weight to subtotal 20 5 8 2 Change active total memory 20 5 8 3 Print single weight 21 5 8 4 Send WiFi 21 5 8 5 Edit clear and print total regist...

Страница 4: ...done to the system must be approved in writing by the supplier prior to any work being completed It is the sole responsibility of the purchaser to train their own employees in the proper use and maint...

Страница 5: ...o stop charging Battery or charger does not work properly exchange battery or charger Storing and or using the battery outside the given temperature range may have a negative effect on the lifetime an...

Страница 6: ...rging after repeated use and after time has passed If the operating time that the battery can be used becomes shorter and shorter it has probably reached the end of its life Note For replacement or ad...

Страница 7: ...The power supply to the system takes place through an exchangeable battery pack With a completely charged battery pack the total weighing time is about 25 hours for a Li ion battery for a system witho...

Страница 8: ...attery 4 1 Low battery indication ProLine 5200 Li An exchangeable battery pack supplies power to the ProLine 5200 Li When the voltage level of the battery pack is running low the battery indicator wil...

Страница 9: ...k and a smart charger After charging for at least 8 hours the charger will shut off when the battery pack is completely full The red LED on the adapter will change to green once the battery is fully c...

Страница 10: ...5 Use 5 1 Use accurate weighing USER MANUAL ProLine 5200 Li 10...

Страница 11: ...it is necessary to check whether the system is unloaded and free If the indicator does not determine the zero point automatically it must be done manually using the 0 key Wrong way of lifting the loa...

Страница 12: ...etting a new zero Out of level Make sure the pallet truck is horizontal Bad calibration No calibration has been saved Scale 1 or reference scale Weight indication Active ID s Custom ID entry Scroll th...

Страница 13: ...or messages Whenever a weighing was not done correctly the weight will turn red and the error is displayed Error Out of level Level switch measures scale is 3 out of level Overload The system has been...

Страница 14: ...5 Net Tare Gross weight 5 5 1 Net weighing automatic tare 1 2 3 4 EXPLANATION Net 1 Tare 2 Gross 3 1 2 3 The indicator is set to zero The NET sign shows that the tare weight is activated Tare 25kg sho...

Страница 15: ...ws the net value of the load weight The gross weight is displayed again NOTE for OIML approved ProLine 5200 Li the tare will be erased automatically when the weight returns to gross zero For the next...

Страница 16: ...lect the desired Preset Tare field If the preset tare you select is empty you have to enter the tare value Confirm with Enter Name your Preset Tare value max 14 characters The NET sign shows that the...

Страница 17: ...ghing mode and is ready for the next weighing NET sign is gone In the tare field None is active 5 6 1 option 1 5 6 2 option 2 Press the preset tare button Select none NOTE For OIML approved ProLine 52...

Страница 18: ...s the ID field On the left side of the button you can activate the ID fields only the active ID fields will be visible on the printout If you press on the right side of the button an ID entry field po...

Страница 19: ...After entering one or more ID codes select your preferred ID and press the back button Press the back button to return to the weighing mode Your active ID codes will now be showed on the print out or...

Страница 20: ...5 8 1 Add weight to subtotal If preferred you can select a total memory The weight is added Load scale Press the key The weight has been added to the selected total memory Select your preferred total...

Страница 21: ...ght Load scale Press the printer key The indicator is now printing The weight is printed and the indicator is ready for the next weighing 5 8 4 Send WiFi First a new weight must be on the display Pres...

Страница 22: ...and press the settings symbol Press Print Total to get a total print out of the selected total register The indicator is printing your receipt If this is shown the connection is lost The weight will...

Страница 23: ...f you want to reset the active total memory after printing press OK Press Clear if you wish to erase all information in this total register Or go back if you don t wish to change the register Change t...

Страница 24: ...ymbol The basic weight symbol is green This means that piece counting has not been activated Press the pcs symbol This symbol now turns green to indicate that piece counting is activated 5 9 1 Activat...

Страница 25: ...t Manual piece weight Enter the piece weight and confirm with Enter The number of pieces are shown in the display 5 9 2 Enter piece weight manually For entering the piece weight manually or calculatin...

Страница 26: ...t will be added or removed from the scale e g 2 Confirm with Enter Note the weight difference should be at least 5 10 kg Press 5 9 3 Calculate piece weight Select Sample PCS weight W1 MAIN 3 4 Automat...

Страница 27: ...mber of pieces that will be added or removed from the scale e g 2 Confirm with Enter Select Sample PCS weight W2 REF Add or remove the given number of pieces from the load Then confirm with OK Automat...

Страница 28: ...the stick is empty or does not contain former weighing data information 2 Insert the stick only when the indicator is turned on 3 Indicator only works with USB stick format FAT32 The data transfer wi...

Страница 29: ...5200 Li 29 5 11 Change the time and date Press arrow down Press on the arrow up down Press the user settings symbol Select User menu Select the parameter you wish to change For this example we change...

Страница 30: ...USER MANUAL ProLine 5200 Li 30 Enter the correct hour Change the cursor to the next value by pressing on the When you are finished press Enter 7 8...

Страница 31: ...the possibility to check the input values of the load cells and the angle position This could be helpful information in case of problems Go into the user menu Select Service help Select Debug Check th...

Страница 32: ...4 1 2 Repeat step 1 4 of chapter 5 11 For the overload signal you can activate 2 setpoints Select a setpoint to set up the values The selected setpoint 1 is now marked Click on the space next to the t...

Страница 33: ...Enter the number of seconds of the time of delay and confirm with Enter Press Back To set up conditions for the delay option select Delay NOTE After you have defined the overload weight you can use th...

Страница 34: ...he values 3 4 Enter the number of kilograms and confirm with Enter The selected setpoint 1 is now marked Click on the space next to the text to reveal multiple options per setpoint 5 6 You can choose...

Страница 35: ...nction and location Tare location only PTare location only Zero location only ID1 Scan location only ID2 Scan location only ID3 Scan location only ID4 Scan location only PT1 Scan location only PT2 Sca...

Страница 36: ...t Button Functions Select the button you wish to change For this example we take the print button Select Function Check the boxes of the actions you want to happen after pressing the Printer button Wh...

Страница 37: ...user menu Select the button you wish to move Printer button for this example If a button is not in use because in this example the printer is installed after delivery The default location is None Sele...

Страница 38: ...ch on the indicator they are back Follow the following steps if you wish to always hide the buttons Go into the user menu Select Display settings The checkbox for Key Functions is checked meaning the...

Страница 39: ...at hh mm 3 Gross weight displays the gross weight For example 233 5 kg or 136 5 lb 4 Net weight displays the net weight For example 233 5 kg or 136 5 lb 5 Tare weight displays the tare weight For exam...

Страница 40: ...40 3 5 7 6 4 Press the settings symbol Now press User Menu The information of the last weighing is shown on the display By pressing Prev you switch to weighings performed prior to the last weighing Pr...

Страница 41: ...is to avoid damage to electronics and load cells The bearings of the wheels non polyurethane and the pivoting points of the levelling bar of the loading wheels must be cleansed and greased regularly...

Страница 42: ...it can be imported in a spreadsheet program on a PC From the app you can enter the ID of an operator or device enter tares automatically or manually zero the weighing system Date and time are automat...

Отзывы: