Calculating the new flow factor
u
Weigh the collected weight (taking into account the empty weight of the collecting vessel).
u
Enter the weight in the "Input collected weight:" menu item.
u
Press the
Enter
key.
The new value is saved in the control unit.
The display shows the menu Calcul. flow factor
The Flow factor must be between 0.4 and 1.9.
u
Specify the flow factor.
To apply the newly calculated flow factor, press the
Enter key
.
To confirm the previously saved flow factor, press the
ESC
key.
The flow factor is saved.
The “Approach drop point” alarm message is displayed.
CAUTION!
Risk of injury due to automatic adjustment of the drop point
When the
Start/Stop
function key is pressed, the drop point is automatically moved to the preset
value by an electrical actuator (Speedservo). This may cause injury.
▶
Before pressing the
Start/Stop
key, ensure that nobody is present in the hazard zone of the
machine.
▶
Acknowledge the “Approach drop point” alarm message by pressing Start/Stop.
The calibration is completed.
4.6.6
PTO speed
Start or stop the transmission
at low PTO speeds only
.
For optimal Idle measurement, check the correct input in the Fertiliser settings menu.
•
The entries in the Spreading disc and Normal disc speed or PTO menu items must
correspond to the actual settings of your machine.
4. Operation
52
5902662