Operation QUANTRON-A
49
4
4.6.6
Calibration test
In this menu, the flow factor is determined based on a calibration test and saved
in the control unit.
Execute the calibration test:
Before spreading for the first time.
If the fertiliser quality has changed significantly (moisture, high dust content,
cracked grain).
If a new fertiliser type is used.
The calibration test must be carried out with the PTO engaged at a standstill or
during travel on a test section.
Remove both spreading discs.
Set the drop point to the calibration test position (DP 0).
Entering the working speed:
1.
Call up the
Fertiliser settings > Start calibration
menu.
2.
Enter the average working speed.
This value is required to calculate the slide position during the calibration test.
3.
Press the
enter key
.
The new value is saved in the control unit.
The
Move to drop point (AXIS only)
alarm is displayed.
4.
Press the
Start/Stop
key.
The drop point is approached.
The alarm is cleared.
The
Prepare calibration
operating screen is displayed.
Selecting the section width:
5.
Determine the spreading side on which the calibration test is to be carried out.
Press the
F1
function key to select the
left
spreading side.
Press the
F4
function key to select the
right
spreading side.
The symbol of the selected spreader side is displayed on a red
background.
NOTICE
The
Calibration
menu is locked for the
M EMC
function and in
AUTO km/h + AUTO kg
operating mode. This menu item is inactive.
n
CAUTION
Risk of injury due to automatic adjustment of the drop point
For machines with electrical drop point actuators, the
Move to
drop point
alarm appears. After pressing the
Start/Stop
function
key, the drop point moves automatically to the preset value by
means of electric servomotors (SpeedServos). This may cause
injuries and material damage.
Before pressing
Start/Stop
, make sure
nobody
is in the
danger zone of the machine.
Содержание QUANTRON-A
Страница 6: ...Table of Contents IV...
Страница 10: ...User instructions 1 4...
Страница 17: ...Layout and function 11 2 Figure 2 5 Control unit display MDS operating screen example 3 11...
Страница 26: ...Layout and function 2 20...
Страница 96: ...Operation QUANTRON A 4 90...
Страница 118: ...Index D...
Страница 120: ......