Spreading operation using the QUANTRON-A control unit
99
5
5.6
Spreading in MAN scale operating mode
In
MAN scale
operating mode, you can manually change the metering slider
opening during spreading.
You are working in
manual
mode only:
If there is no speed signal (radar or wheel sensor not available or defective),
When spreading slug pellets or fine seeds.
MAN scale
operating mode is useful for slug pellets and fine seeds because the
automatic mass flow control cannot be activated due to the low weight loss.
Precondition:
The metering sliders are open (activation with the
Start/Stop key
).
On the
MAN scale
operating screen, the symbols for the section widths are
filled in red.
Figure 5.5:
MAN scale operating screen
[1] Display of the current metering slider scale position
11.
To change the metering slider opening, press the
F2
or
F3
function key.
F2
:
MAN+
to increase the metering slider opening or
F3
:
MAN-
to reduce the metering slider opening.
NOTICE
For even spreading of the spreading material, you need to work at a
constant
forward speed
in manual mode.
NOTICE
In order to achieve optimum spreading results in manual mode as well, it is
recommended to take the metering slider opening and forward speed values
from the fertiliser chart.
1
Содержание QUANTRON-A
Страница 6: ...Table of Contents IV...
Страница 10: ...User instructions 1 4...
Страница 17: ...Layout and function 11 2 Figure 2 5 Control unit display MDS operating screen example 3 11...
Страница 26: ...Layout and function 2 20...
Страница 96: ...Operation QUANTRON A 4 90...
Страница 118: ...Index D...
Страница 120: ......