Spreading operation using the QUANTRON-A control unit
97
5
5.4
Spreading in AUTO km/h operating mode
In AUTO km/h operating mode, the control unit automatically controls the
actuator depending on the speed signal.
1.
Make the fertiliser settings:
Application rate (kg/ha)
Working width (m)
2.
Pour in the fertiliser.
3.
Carry out a calibration test to determine the flow factor
or
Obtain the flow factor from the fertiliser chart.
4.
Enter the flow factor manually.
5.
Press the
Start/Stop
key.
The spreading starts.
NOTICE
In order to achieve optimum spreading results in AUTO km/h operating mode,
a calibration test is to be carried out before starting the spreading work.