u
Tighten the screw connection with a torque
wrench (torque =
300 Nm
).
Fig. 63: Fastening the weigh cells (right side in
direction of travel)
u
Tighten the screw connection [1] with a
torque wrench (torque =
65 Nm
).
Fig. 64: Fastening the tie rod at the weigh frame
After tightening the screw connections with the torque wrench, the weighing system is to be tared
again. Please follow the instructions in the chapter
Zeroing the scales
of the operator’s manual of
the control unit.
11.3
Opening the protective grid in the hopper
n
Protective grid lock
WARNING!
Risk of injury due to moving parts in the hopper
There are moving parts in the hopper.
There is a risk of injury to hands and feet during commissioning and operation of the machine.
u
Install and the lock the protective grid before commissioning and operating the machine at all
times.
u
The protective grid may
only
be opened for maintenance purposes or in the event of a fault.
11. Maintenance and service