Operation AXIS ISOBUS
51
4
4.6.2
Machine settings with the M EMC function
Open the
Machine settings
menu.
Figure 4.13:
Machine settings menu, page 1 and 2
AUTO/MAN mode
The machine control unit automatically controls the metering quantity according
to the forward speed signal. The application rate, working width and flow factor
are taken into account.
By default, the unit is operated in the
automatic
mode.
Automatic mode with automatic mass flow control (AUTO km/h + Auto kg)
The
AUTO km/h + AUTO kg
operating mode continuously controls the fertiliser
quantity during spreading according to the forward speed and the fertiliser’s flow
behaviour. This optimises the metering of the fertiliser.
NOTICE
Spreading in different operating modes is described in chapter
eration with the machine control unit AXIS ISOBUS, page 73
.