Alarm messages and possible causes
63
6
6
Alarm messages and possible causes
Various alarm messages can be displayed on the AXENT ISOBUS machine con-
trol unit display.
6.1
Meaning of the alarm messages
Message in display
Possible cause/action
Error at left pre-metering slider cylin-
der
The position at the left pre-metering slide could not be
reached
Blockage
Hydraulic cylinder defective
Error at right pre-metering slider cylin-
der
The position at the right pre-metering slide could not be
reached
Blockage
Hydraulic cylinder defective
AXENT empty
The hopper is empty.
Function-Stop
All connected devices are in a safe condition.
The stop switch was operated.
Spreader overloaded!
The machine is overloaded
The load inside the machine exceeds 10,000 kg
Manual mode active. Risk of fertiliser
overflow.
The message is displayed on switching over from auto-
matic to manual.
Cover open!
Switch is not operated, the loading function is not possi-
ble.
The rear cover is open and not properly closed.
Stop loading!
The message is displayed on switching over to the sys-
tem/test menu during operation.
1. Stop spreading operation.
2. Open the system/test menu.
Low oil level!
Insufficient oil level in the hydraulic circuit.
Stop the machine and refill oil.
Cannot be selected!
The operating mode set in the AXIS H ISOBUS machine
control unit does not comply with the settings of the AX-
ENT ISOBUS machine control unit.
Set the correct operating mode. See
Belt speed not reached
The conveyor belt has not reached the target speed
within 5 s.