If you have obtained the value from earlier calibrations or from the fertilizer chart, enter it
manually
in
this selection window.
u
Access the menu Fertiliser settings > Turns/kg.
The currently set number of revolutions per kilogram will appear in the window.
u
Enter the value in the input field.
u
Press
OK
.
The new value is saved in the machine control unit.
If you do not know the calibration factor:
u
Enter the value
1.5
turns/kg.
u
Make sure
to execute a calibration.
The calibration factor for this fertilizer is determined precisely.
4.5.3
Calibration
You execute the calibration to calibrate the precise amount of fertilizer. Fertilizer must be filled into the
hopper. Calibrations for up to 4 types of fertilizers can be stored.
Execute the calibration:
•
Before spreading for the first time
•
If the fertilizer quality has changed significantly (moisture, high dust content, granulate damage)
•
If a new fertilizer type is used
The calibration must either be conducted with a running PTO at a standstill or while driving over a test
section.
4. Operation
24
5903001
AERO ISOBUS
Содержание AERO ISOBUS
Страница 16: ...2 3 Structural menu overview 2 Layout and function 16 5903001 AERO ISOBUS...
Страница 54: ...Fig 30 Button functions Level 1 Fig 31 Button functions Level 2 4 Operation 54 5903001 AERO ISOBUS...
Страница 62: ...For this purpose follow the instructions on screen 6 Alarm messages and possible causes 62 5903001 AERO ISOBUS...
Страница 65: ......
Страница 66: ......