6 | Electrical connection
80.06.243_iVario Pro L_XL_IM_V01_en-US
45 / 60
The socket in the device can be equipped with an optional integrated residual
current circuit breaker that switches off the socket in the event of residual cur-
rent. Check the socket in the device for correct function before commissioning
for the first time.
Checking the function
When the device is switched on, the socket is inactive.
a
The device is connected to the power grid.
1. Press the Reset/On LED button.
>
The LED button above Reset/On lights up and the socket is functional.
2. Press the Test/Off LED button.
>
The LED button above Test/Off lights up and the socket is not functional.
>>
The function of the socket has been checked.
Malfunction of the socket in the device
Both LED buttons do not light up.
n
If the Test/Off LED button does not extinguish when pressed, the residual
current circuit breaker may be faulty.
n
The fuse on the residual current circuit breaker may be faulty.
n
If the fuse is functional, the residual current circuit breaker may be faulty.