6 | Electrical connection
50 / 96
80.06.083_iCombiPro-iCombiClassic_IM_en-US
>>
The electrical compartment is open.
6.3
Connecting the electrical devices to the power grid
Notes on the power cable and connection point
n
There is a fixed connection for the electrical connection of the device.
n
Devices with a 3 NAC 400 V connection voltage can be connected via a
fixed connection (conduit connection) or connection with a safety switch.
n
You have your own supply cable on hand for the device.
n
The devices are supplied without a power cable.
n
Device size XS GN: The device is delivered with a power cable.
n
The connection point of the power cable is on the main contactor in the
electrical compartment behind the removable left side wall.
Making the connection on the table device
a
Device size XS GN: For the installation, there is an all-pole disconnecting
device with a contact distance of at least 3 mm [0.12 inch].
a
A type B fault-current circuit breaker is recommended.
a
A type A fault-current circuit breaker can be used for device size XS GN.
a
The strain relief for the power cable is tightened.
a
The electrical compartment is open.
1. Feed the power cable through the opening on the rear side into the elec-
trical compartment to the connection point.
2. Connect the wires to the terminals. Observe the following color coding.
3. Check that the conductors are connected correctly.
>>
The device is connected to the power grid.