Diagnostic Test: Press
Enter 2 6 Play/Pause
phone will play back (5) Beeps (1st Beep=External Power
Supply; 2nd Beep=LED; 3rd Beep=Microphone; 4th Beep=Speaker; 5th Beep=Back-Up Battery). If any item fails
during test you will hear a Blat not a Beep. If you hear a Blat, contact the Rath Microtech Technical Dept.
Connect to standard RJ11 phone jack. If splicing connection, only hook up Red and Green Wires from the phone cable.
If connecting to a SmartRescue unit, you must connect all four wires. (Check for 24vdc or 48vdc supply at the splice)
Initial Set-Up:
If the phone does not respond, make sure the green LED (D1) on the circuit board is lit. If not, check to be sure the power is
properly connected.
3.
If the phone dials only one digit and hangs-up, there is another Auto-Dialer on the line. You need to re-wire the system so
that our unit is either in parallel or ahead of it.
1.
2.
If the phone dials a couple of digits and gets a busy signal, the unit is installed on a switchboard line and needs to be
programmed to dial the appropriate access code to get an outside line. (Usually an 8 or 9)
Troubleshooting:
N56 W24720 N. Corporate Circle Sussex, WI 53089
800-451-1460 262-246-4828 (fax) www.rathmicrotech.com
05/10
Made in the USA
3 Year Warranty
Revision 1
Troubleshooting & Diagrams
SmartPhone VI
1.
2.
Wiring Diagrams: 12v Models
Transf-12v
To 120 vac
Black/Hot
12+ 12-
To 12 Volt Power
Supply
Enter
Record
Play/Pause
Stop
Bat
RJ1
1
RJ1
1
R
elay Alar
m
LED Switc
h
To Phone Line
MIC Speaker
+ -
RJ1
1
RJ1
1
To Phone Line
White/Neutral
12v
AC/DC
Direct 12 vac/dc Powered
Note:
If utilizing our
Modem
feature,
connect to our
“Relay
Connection”
Note:
If utilizing our
Modem
feature,
connect to our
“Relay
Connection”
120 vac to 12 vac/dc Powered
Enter
Record
Play/Pause
Stop
Bat
R
elay Alar
m
LED Switc
h
MIC Speaker
+ -
12v
AC/DC
Twisted,
shielded pair
Twisted,