background image

Ratek TH8500 Programmable Immersion Heater Circulator - User Manual 

------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- 

------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- 

Page 5 of 28

 

 

The operator shall be aware that the protection provided by the equipment may be impaired if the equipment is used with 
accessories not provided or recommended by the manufacturer, is modified in any way or is used in a manner not 
specified by the manufacturer.

 

 

The operator is responsible for ensuring all users of the product are qualified to do so, and are well versed in common 
safety concepts. The product should only be operated by an adult who has read and understood this User Manual 
provided in the appropriate language in its entirety.

  

 

Any user must be informed by the responsible operator of any potential hazards that may arise through the use of this 
equipment in the course of their work, including any local environmental hazards not related directly to the Immersion 
Heater Circulator. They should also be able to demonstrate that they understand any preventative safety measures in 
operation prior to operating the equipment. 

 

The operator shall agree to accept responsibility for the use of the equipment in accordance with this User Manual, and 
be fully aware that the equipment is designed for commercial use.  

 

It is assumed that the user and operator have had experience in a commercial environment, and had appropriate training 
in how to perform their work safely in accordance with any local operational health and safety regulations. The operator 
and all users should be well versed in local emergency procedures as per the workplace safety regulations in effect. 

 

Avoid any direct impact with any surface of the equipment, including the casing, cover panel, element, pump or control 
panel. 

 

Important: 

Do not use any sharp or pointed metal objects anywhere near the equipment, in particular the control panel. 

 

Avoid using the equipment near any other vibrating equipment or source of excessive vibration. 

 

Ensure the equipment is cleaned and maintained in accordance with this User Manual. 

 

Ensure that all original safety warning labels are in an adequate, legible condition and are firmly affixed to the equipment 
before using the product. 

 

Plug the equipment directly into a wall power outlet. Do not plug the equipment into a multi-socket adapter of any kind. 

 

The equipment is intended for operation in a controlled electromagnetic environment. Avoid the use of transmitting 
devices (e.g. cellular or mobile telephones) near the equipment whilst operating. A minimum distance of 2 Metres from 
the product is recommended for any transmitting device. 

 

Important: 

The equipment must only be installed and operated in 

well ventilated areas

. The unit is not intended for use 

in explosive atmospheres, in confined spaces or inside any other piece of laboratory equipment such as humidity cabinets 
or incubators. 

 

The allowed operating environment must be between 5° Celsius and 40° Celsius ambient air temperature. Be aware that 
the ambient air temperature will limit the minimum controllable water temperature. The ambient air temperature must be 
at least 7° Celsius lower than the desired controllable water temperature. 

 

The maximum allowed relative humidity of the operating environment is 80%. 

 

The equipment should not be stored in direct sunlight, near chemicals, or other contaminants. 

 

If any of these safety recommendations cannot be achieved or the equipment has been damaged in any way, the 
equipment should not be installed or operated. 

 

Important : 

If you have any concerns or questions relating to operator or user safety, please contact the appropriate 

Ratek Customer Service department before installing and operating the unit. Contact details are provided in this User 
Manual. 

 

Safety Labels And Markings 

 
The equipment is provided with safety caution labels. An explanation of each caution label is provided below. It is the 
responsibility of the operator and user to fully understand the meaning of these warning labels prior to operating the 
equipment. 
 

Very Important: Particular care should be taken when working near the heating element at the bottom of the Immersion 

Heater Circulator. At all times during operation the supplied safety guard MUST REMAIN FITTED to the Immersion Heater 

Circulator to avoid possible burns or scalds from the heating element. 

  

The operator or user must also take extreme care when the bath is working at temperatures above 50° C as steam will be 

present and can cause scalding. 

Содержание TH8500

Страница 1: ...www ratek com au www ratek com au www ratek com au www ratek com au 60 Wadhurst Dve Boronia Victoria 3155 Australia P 613 9887 2161 F 613 9887 2163 E sales ratek com au All Rights Reserved Made in Au...

Страница 2: ...the condition of the product to ensure it has not been damaged in transit Any damage should be reported immediately to the responsible carrier If the product is damaged in any way re pack the product...

Страница 3: ...ion 10 Unpacking and Installing 10 Filling The Water Bath 11 Adjusting the Mounting Clamp 12 Adjusting the Pump Flow Rate 12 Attaching a Hose For External Pump Out 13 Connecting Power 13 Switching On...

Страница 4: ...r use in a clean laboratory environment only where adequate ventilation a good power supply and provisions for routine cleaning are available The Immersion Heater Circulator should not be used outdoor...

Страница 5: ...he equipment before using the product Plug the equipment directly into a wall power outlet Do not plug the equipment into a multi socket adapter of any kind The equipment is intended for operation in...

Страница 6: ...es Colours Black on a yellow background The Immersion Heater Circulator is fitted with a removable guard which protects against contact with the heating element This guard MUST REMAIN FITTED at all ti...

Страница 7: ...ollowing operating procedures before installing or operating the Immersion Heater Circulator in order to achieve the best performance and maximum attainable user safety Identification of Controls Func...

Страница 8: ...il water Safety Warnings Throughout this User Manual specific warnings will be supplied which relate to the current operation being referred to These warnings are supplied in addition to the main warn...

Страница 9: ...serious injury or danger to life CAUTION Always work above the level of the Immersion Heater Circulator to avoid spillage of dangerously hot water At no point should the user operator animal or any ot...

Страница 10: ...ath to allow for adequate ventilation and for steam to dissipate Ensure that there is a suitable mains power supply outlet within reach of the supplied mains power lead without placing any strain what...

Страница 11: ...ur Immersion Heater Circulator before filling the water bath if you are unsure of your water supply CAUTION Before filling the water bath ensure the mains power supply outlet is switched off and that...

Страница 12: ...th as required Once the depth has been set re tighten the 2 clamp screws by gently tightening in a clockwise direction Step 2 Once the unit is placed on the bath gently tighten the thumb screw by turn...

Страница 13: ...diameter no larger than 15mm Silicon hose is recommended for most applications Simply push the hose over either outlet until it touches the guard a hose clamp may be used if required however this is...

Страница 14: ...s power supply outlet Switching On The Immersion Heater Circulator CAUTION Ensure you have filled the water bath to at least the minimum required level before switching on power Failure to do so may c...

Страница 15: ...am and splashing of water when the Immersion Heater Circulator is operating at these high temperatures particularly whilst loading and unloading containers racks or accessories ALWAYS use appropriate...

Страница 16: ...ow You should choose an appropriate profile number based on the maximum number of segments your profile will require Profile Numbers Maximum Number of Segments 1 thru 4 16 5 thru 7 32 8 and 9 64 To co...

Страница 17: ...ts enter the number of times the profile should be repeated cycled The target set point in C for a ramp type segment Time duration or ramp rate for a ramp type segment entered in units specified at Al...

Страница 18: ...elected segment Note Press simultaneously to move backwards through the profile parameters Once you finished entering your profile parameters push to exit the profile menu and return to the normal sta...

Страница 19: ...le by the user The alarms are configured as deviation alarms whereby they operate relative to the desired set point If the current temperature deviates from the set temperature by the margin configure...

Страница 20: ...uch as silicon insulated tongs to slowly remove the items and place them onto a water proof and heat proof surface Continue to load or unload your containers racks or accessories until complete Switch...

Страница 21: ...eets the environmental conditions required as detailed in the technical specifications of this User Manual Turn off the Mains Power Switch by setting it to the position marked with a circle Unplug the...

Страница 22: ...make any part of the control panel any exposed control or receptacle or any part of the Immersion Heater Circulator excessively wet If these receptacles and controls remain wet once electrical power...

Страница 23: ...s Power Switch Unplug the equipment from the mains power supply outlet and remove it from the water bath Empty the water bath Fill the water bath with enough cold water to just cover the top coil of t...

Страница 24: ...used an unpleasant smell may also be noticed as a result of the impurities in the water becoming hot This is normal Once the test has been completed turn off power to the Immersion Heater Circulator...

Страница 25: ...use Altitude up to 2 000 Metres Temperature 5 Celsius to 40 Celsius Ambient temperature will limit the minimum achievable water temperature Maximum relative humidity 80 for temperatures up to 31 Cels...

Страница 26: ...the contact details provided in the section of this User Manual titled Ratek Service Contact Information if you believe your equipment is exhibiting a fault condition Warranty Conditions This Ratek pr...

Страница 27: ...der the Warranty you must present the product together with proof of purchase or issue to the store where you purchased the product from If the product is defective and does meet the Warranty you will...

Страница 28: ...ammable Immersion Heater Circulator User Manual Page 28 of 28 Provide a full and complete fault description and your return contact details in the package and return the product as advised by the serv...