13
English
To set the timer
To turn ON or OFF the unit at a preset time.
TIMER
SET
CANCEL
ON
OFF
1
2
3
CANCEL
3
2
1
3
1
Select ON or OFF
timer
Example:
OFF at 22:00
OFF
OFF
TIMER
2
Set the time
2
OFF
TIMER
3
Confi rm
SET
OFF
TIMER
TIMER
• To cancel ON or OFF timer, press
ON
or
OFF
then press
CANCEL
.
• When ON Timer is set, the unit may start
earlier (up to 15 minutes) before the actual
set time in order to achieve the desired
temperature on time.
• Timer operation is based on the clock set in
the remote control and repeats daily once set.
For clock setting, please refer to Quick guide.
• If timer is cancelled manually or due to power
failure, you can restore the previous setting
(once power is resumed) by pressing
SET
.
NANOE-G
To purify the air
NANOE-G
• nanoe-G starts automatically when the unit is turned
on with
OFF/ON
.
• Can be activated even when the unit is turned off .
In this condition, the unit will operate as a fan with
AUTO fan speed and fl ap swing.
To deactivate viruses/bacteria on the fi lter
NANOE-G
POWER
• After the unit is turned off , the nanoe-G in-fi lter
deactivation may activate up to 150 minutes.
Turning on the unit cancels this operation
nanoe-G in-fi lter deactivation
• Depending on the unit’s accumulated operation time,
nanoe-G in-fi lter deactivation may activate only once a
day after the unit turned off .
• To remove the moisture left in the internal parts, the
fan will operate for 30 minutes with fl ap opened slightly.
This process only applicable when the unit is operated
in COOL/DRY mode before turned off . Then, nanoe-G
deactivates viruses/bacteria on the fi lter for 2 hours with
fan stopped and fl ap closed.
• Do not turn off the power supply during this operation.
After power failure, this operation will not resume.
AIR SWING
To adjust vertical airfl ow
direction
(Remote control display)
• Keeps the room ventilated.
• In COOL/DRY mode, if AUTO is set, the fl ap swings
up/down automatically.
• Do not adjust the fl ap by hand.
Note
POWERFUL/
QUIET
,
NANOE-G
• Can be activated in all modes and can be
cancelled by pressing the respective button
again.
POWERFUL/
QUIET
• Cannot be selected at the same time.
Auto Restart Control
• If power is resumed after a power failure, the
operation will restart automatically after a period
of time with previous operation mode and airfl ow
direction.
• This control is not applicable when TIMER is set.
Operation conditions
Use this air conditioner under the following
temperature range.
DBT : Dry bulb temperature
WBT : Wet bulb temperature
Temperature
°C (°F)
Indoor
Outdoor
DBT
WBT
DBT
WBT
COOL
Max.
32
(89.6)
23
(73.4)
43
(109.4)
26
(78.8)
Min.
16
(60.8)
11
(51.8)
16
(60.8)
11
(51.8)