4

0

Φ6 - 6.35(1/4")

Φ9.52(3/8")

Φ12-12.7(1/2")
Φ15.8-16(5/8")

1.3

0.7

1.6

1.0

1.8

1.0

2.4

2.2

Pipe expanding method

Note:

Improper pipe expanding is the main cause of refrigerant leakage. Please expand
the pipe according to the following steps:

A: Cut the pipe

● Confirm the pipe length according to 

   the distance of indoor unit and 
   outdoor unit.

● Cut the required pipe with pipe cutter.

pipe

pipe cutter

leaning

uneven

burr

B: Remove the burrs

● Remove the burrs with shaper and

   prevent the burrs from getting into 
   the pipe.

downwards

pipe

shaper

C: Put on suitable insulating pipe

D: Put on the union nut

● Remove the union nut on the indoor

   connection pipe and outdoor valve; 
   install the union nut on the pipe.

union pipe

pipe

E: Expand the port

● Expand the port with expander.

Note:

● "A" is different according to the

   diameter, please refer to the sheet 
   below:

expander

hard
mold

pipe

F: Inspection

● Check the quality of expanding port. 

    If there is any blemish, expand the 
    port again according to the steps 
    above.

the length is equal

improper expanding

leaning

damaged

surface

crack

uneven
thickness

smooth surface

Outer diameter

(mm)

A(mm)

Max

Min

Содержание RS-V12KE

Страница 1: ...i a e p y t t i l p s c i n o s a R g n i s a h c r u p r o f u o y k n a h T manual carefully before installation and well keep this manual for your future reference Some figures in this manual may not match the real object just for reference only Model RS V12KE RU V12KE RS V9KE RU V9KE RS V18KE RU V18KE RS V24KE RU V24KE ...

Страница 2: ......

Страница 3: ...for electric connection 27 Installation Installation of indoor unit 28 Installation of outdoor unit 33 Vacuum pumping 36 Leakage detection 36 Check after installation 37 Test and operation Test operation 37 Attachment 38 Pipe expanding method Configuration of connection pipe 40 This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities...

Страница 4: ......

Страница 5: ...njury or property loss is caused by the following reasons Indicates a hazardous situation that if not avoided will result in death or serious injury Indicates a hazardous situation that if not avoided could result in death or serious injury Indicates a hazardous situation that if not avoided may result in minor or moderate injury Indicates important but not hazard related information used to indic...

Страница 6: ... appliance Cleaning and user maintenance shall not be made by children without supervision years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved Do not wash the air conditioner with water to avoid electri...

Страница 7: ...damage 2 Precautions WARNING conditioner and disconnect power immediately and then If the air conditioner operates under abnormal conditions it may cause malfunction electric shock or fire hazard Do not spill water on the remote controller otherwise the electric shock or damage Please contact dealer when you need to repair air conditioner Do not repair air conditioner by yourself It may cause obje...

Страница 8: ...re neutral wire and any work related to electricity and safety Be sure to cut off the power supply before proceeding Including an circuit breaker with suitable capacity please Air Conditioner should be properly grounded Incorrect Don t use unqualified power cord grounding may cause electric shock According to the local safety regulations use qualified Installation must be performed by qualified pr...

Страница 9: ...hould be connected by a professional national wiring regulations requirement by authorized personnel only 4 Precautions WARNING wire which can t be used for other purposes The grounding resistance should comply with national electric safety regulations The air conditioner is the first class electric appliance It keep the interconnection cable away from the copper tube The temperature of refrigeran...

Страница 10: ... relocate the air conditioner to another must be installed in the line For the air conditioner without plug an circuit breaker Select a location which is out of reach for children and For the air conditioner with plug the plug should be Precautions WARNING Working temperature range Indoor side DB WB Outdoor side DB WB Maximum cooling 32 23 43 26 Maximum heating 27 24 18 for heat pump model only Th...

Страница 11: ...please refer to actual products Parts name Indoor Unit Outdoor Unit air inlet panel aux button horizontal louver air outlet remote controller Actual product may be different from above graphics please refer to actual products air inlet connection wire air outlet NOTICE ...

Страница 12: ...Display content or position may be different from above graphic please refer to actual product Display Heating indicator Temp indicator Cooling indicator Power indicator Receiver window Drying indicator Display 7 ...

Страница 13: ...R ON TIMER OFF button 8 SLEEP button 5 button Send signal Turbo mode 8 heating function Set temperature Set time X FAN function TIMER ON TIMER OFF Child lock Up down swing Left right swing Light Temp display type Set temp Outdoor ambient temp Indoor ambient temp Sleep mode Clock Heat mode Fan mode Dry mode Cool mode Auto mode Operation mode I feel Air purification function Ventilation function Qui...

Страница 14: ...st fan blowing angle After putting through the power the air conditioner will give out a sound Operation indicator is ON red indicator After that you can operate the air conditioner by using remote controller Under on status pressing the button on the remote controller the signal icon on the display of remote controller will blink once and the air conditioner will give out a di sound which means t...

Страница 15: ...t super high fan speed to cool or heat quickly so that the ambient temp approachs the preset temp as soon as possible button 5 Press or button once increase or decrease set temperature 1 F Holding or button 2s later set temperature on remote controller will tor on indoor unit will change accordingly Temperature can t be adjusted under auto mode When setting TIMER ON TIMER OFF or CLOCK press or but...

Страница 16: ...tion Horizontal louver will stop at the fixed position When selecting air conditioner is blowing fan at fixed angle Horizontal louver will send air at the fixed angle Hold button above 2s to set your required swing angle When reaching your required angle release the button Note may not be available When air conditioner receives this signal the air conditioner will blow fan automatically Press this...

Страница 17: ... within 2s the change of swing status will also depend on the circulation sequence stated above 8 SLEEP button Under COOL HEAT or DRY mode press this button to start up sleep function icon is displayed on remote controller Press this button again to cancel sleep function and icon will disappear After powered on Sleep Off is defaulted After the unit is turned off the Sleep function is canceled In t...

Страница 18: ... running for a while at low speed In this period press X FAN button to stop indoor fan directly Having set X FAN function off After turning off the unit by pressing ON OFF button the complete unit will be off directly Press this button to set clock time icon on remote controller will blink Press or button within 5s to set clock time Each pressing of or button clock time will increase or decrease 1...

Страница 19: ...roller Only for the models whose indoor unit has dual 8 display When selecting displaying of indoor or outdoor ambient temperature indoor temperature indicator displays corresponding temperature and automatically turn The ventilation function is not applicable to this model 15 Press this button to achieve the on and off of air purification and ventilation functions in LCD displays Press the button...

Страница 20: ...CLOCK buttons simultaneously to start up or turn off 8 heating function When this function is started up and 8 will be shown on remote controller and the air conditioner keep the heating status at 8 Press TEMP and CLOCK buttons simultaneously again to exit 8 heating function Note Under 8 heating function fan speed is defaulted at auto speed and it can t be adjusted Under 8 heating function set tem...

Страница 21: ...nder at the receiving window on indoor unit The distance between signal sender and receiving window should be no more than 8m and there should be no obstacles between them Signal may be interfered easily in the room where there is fluorescent lamp or wireless telephone remote controller should be close to indoor unit during operation Replace new batteries of the same model when replacement is requi...

Страница 22: ...ock Turn off the air conditioner and disconnect the power before cleaning the air conditioner to avoid electric shock Do not use volatile liquid to clean the air conditioner Do not use liquid or corrosive detergent clean the appliance and do not splash water or other liquid onto it otherwise it may damage the plastic components even cause electric shock Do not remove the panel when cleaning it WAR...

Страница 23: ... the filter is very dirty use the water below 45 to clean it and then put it in a shady and cool place to dry Install the filter and then close the panel cover tightly The filter should be cleaned every three months If there is much dust in the operation environment clean frequency can be increased After removing the filter do not touch fins to avoid injury Do not use fire or hair dryer to dry the...

Страница 24: ... pipe is damaged 1 Disconnect power supply 2 Clean filter and indoor unit s panel 3 Check whether mounting bracket for outdoor unit is damaged or corroded If yes please contact dealer Notice for disposal 1 Many packing materials are recyclable materials Please dispose them in appropriate recycling site 2 If you want to dispose the air conditioner please contact local dealer or consultant service c...

Страница 25: ...room Pull out the plug Reinsert the plug after about 3min and then turn on the unit again Signal receiving range is 8m Remove obstacles Select proper angle and point the remote controller at the re ceiving window on indoor unit Check the batteries If the power of batteries is too low please replace them Take the remote controller close to indoor unit Turn off the fluorescent lamp and then try it ag...

Страница 26: ...or temperature and hum idity is high Because indoor air is cooled rapidly After a while indoor temperature and humidity will be decrease and mist will disappear Phenomenon Check items Solution Set temper ature can t be adjusted Unit is operating under auto mode Temperature can t be adju sted under auto mode Please switch the operation mode if you need to adjust temperature Your required temperatur...

Страница 27: ...ed on During defrosting under he ating mode it may generate vapor which is a normal phenomenon Water flowing noise Air conditioner is turned on or turned off just now The noise is the sound of refrigerant flowing inside the unit which is a normal phenomenon Cracking noise Air conditioner is turned on or turned off just now This is the sound of friction caused by expansion and or contraction of pan...

Страница 28: ...ated after restarting the unit If not please H3 It can be eliminated after restarting the unit If not please C5 F0 F1 F2 WARNING When below phenomenon occurs please turn off air conditioner and discon Power cord is overheating or damaged There s abnormal sound during operation Air switch trips off frequently Air conditioner gives off burning smell Indoor unit is leaking If the air conditioner oper...

Страница 29: ... At least 30cm At least 300cm At least 200cm Space to the floor Space to the obstruction Space to the obstruction Space to the obstruction Space to the ceiling Space to the obstruction Space to the obstruction At least 30cm At least 15cm At least 15cm Space to the wall Space to the wall Space to the wall ...

Страница 30: ...ry make sure that liquid valve and gas valve are fully closed and power is disconnected before detaching the connection pipe If compressor starts running when stop valve is open and connection pipe is not yet connected air will be sucked in and cause pressure rise or compressor rupture resulting in injury When installing the unit make sure that connection pipe is securely connected before the comp...

Страница 31: ... of installation dimension diagram Select a location which is out of reach for children and far away from animals or plants If it is unavoidable please add the fence for safety purpose 5 Tools for installation Selection of installation location Basic requirement Installing the unit in the following pla ces may cause malfunction If it is un avoidable please consult the local dealer 3 4 Select a loc...

Страница 32: ...le away from the copper tube 9 The appliance shall be installed in accordance with national wiring regulations grounding with specialized grounding device by a professional Please make sure it is always grounded effectively otherwise it may cause electric shock 2 The yellow green wire in air conditioner is grounding wire which can t be used for other purposes 3 The grounding resistance should comp...

Страница 33: ...l slightly downward to the outdoor side with the gradient of 5 10 Left Wall Φ70mm Right Mark in the middle of it Level meter Rear piping hole Wall Space to the wall above 150mm Space to the wall above 150mm Φ70mm Rear piping hole RS V12KE RS V18KE RS V24KE RS V9KE Left Wall Φ55 Right Mark in the middle of it Level meter Rear piping hole Wall Space to the wall above 150mm Space to the wall above 15...

Страница 34: ...out the pipe from left or right please cut off the corresponding hole on the bottom case cut off the hole left right 1 The pipe can be led out in the direction of right rear right left or rear left left rear left right rear right Step four outlet pipe Installation of indoor unit union nut pipe joint pipe Indoor 5 10 outdoor Φ55 Φ70 2 Pretighten the union nut with hand Note Pay attention to dust pr...

Страница 35: ...he indoor drain hose in order to prevent condensation The plastic expansion particles are 1 Open the panel remove the screw on the wiring cover and then take down the cover wiring cover screw panel Step seven connect wire of indoor unit 4 Wrap the indoor pipe and joint of con Installation of indoor unit torque wrench open end wrench indoor pipe pipe union nut Hex nut diameter Tightening torque N m...

Страница 36: ... and the contact parting distance should be more than 3mm 3 Remove the wire clip connect the power connection wire to the wiring terminal according to the color tighten the screw with wire clip Outdoor unit connection Note the wiring board is for reference only please refer to the actual one power connection wire cable cross hole 2 Make the power connection wire go through the cable cross hole at ...

Страница 37: ...eparately at the end Note The power cord and control wire can t be crossed or winding The drain hose should be bound at the bottom drain hose band connection pipe indoor power cord Step nine hang the indoor unit 1 Put the bound pipes in the wall pipe and then make them pass through the wall hole 2 Hang the indoor unit on the wall mounting frame 3 Stuff the gap between pipes and wall hole with seal...

Страница 38: ...stallation situation 1 Select installation location according to the house structure 2 Fix the support of outdoor unit on the selected location with expansion screws 1 Place the outdoor unit on the support Fix the foot holes of outdoor unit with bolts 2 2 Connect the drain hose into the drain vent foot holes foot holes chassis outdoor drain joint drain vent Drain hose Connect the outdoor drain joi...

Страница 39: ...ow handle screw gas pipe liquid pipe liquid valve gas valve union nut pipe joint Hex nut diameter Tightening torque N m Φ 6 Φ 9 52 Φ 12 Φ 16 Φ 19 30 40 45 55 60 65 70 75 15 20 1 Remove the wire clip connect the power connection wire and signal control wire only for cooling and heating unit to the wiring terminal according to the Note the wiring board is for reference only please refer to the actua...

Страница 40: ...outlet pipe hole of indoor unit Slant the drain hose slightly dow nwards The drain hose can t be The water outlet can t be placed in water in order to drain smoothly Installation of outdoor unit U shaped curve wall drain hose the drain hose can t raise upwards The drain hose can t be fluctuant The drain hose can t be fluctuant The water outlet can t be fluctuant The water outlet can t be placed in...

Страница 41: ...sure decreases there may be leakage 5 Remove the piezometer open the valve core of liquid valve and gas valve completely with inner hexagon spanner 6 Tighten the screw caps of valves and refrigerant charging vent Use vacuum pump liquid valve gas valve refrigerant charging vent nut of refrigerant charging vent vacuum pump piezometer valve cap Lo Hi inner hexagon spanner open close 1 With leakage de...

Страница 42: ... the speci fication It may cause malfunction or damaging the parts Is there any obstruction in the air inlet and outlet It may cause insufficient cooling heating capacity The dust and sundries caused during installation are removed It may cause malfunction or damaging the parts The gas valve and liquid valve of connection pipe are open completely It may cause insufficient cooling heating capacity 1 P...

Страница 43: ... of liquid pipe Basing on the length of standard pipe add refrigerant according to the requirement as shown in the table The additional refrigerant charging amount per meter is different according to the diameter of liquid pipe See the following sheet Additional refrigerant charging amount prolonged length of liquid pipe additional refrigerant charging amount per meter Configuration of connection ...

Страница 44: ...eter of connection pipe Liquid pipe mm Gas pipe mm Φ6 Φ6 or Φ9 52 Φ12 Φ16 Φ19 Φ22 2 Φ9 52 or Φ12 Φ16 or Φ19 Φ19 or Φ22 2 Φ25 4 or Φ31 8 _ _ Cooling only g m Cooling and heating g m 15 15 30 60 250 250 350 350 120 120 50 20 Outdoor unit throttle Configuration of connection pipe ...

Страница 45: ... and prevent the burrs from getting into the pipe downwards pipe shaper C Put on suitable insulating pipe D Put on the union nut Remove the union nut on the indoor connection pipe and outdoor valve install the union nut on the pipe union pipe pipe E Expand the port Expand the port with expander Note A is different according to the diameter please refer to the sheet below expander hard mold pipe F ...

Страница 46: ...41 If this product is out of order under proper use a free repair service is available within warranty period Any defective part which has been replaced shall become our property ...

Страница 47: ......

Страница 48: ...RSE0420 66129935220 ...

Отзывы: