background image

12

Introduction for buttons on remote controller

I FEEL button

9

Press this button to start I FEEL function and "     " will be displayed on the remote
controller. After this function is set, the remote controller will send the detected
ambient temperature to the controller and the unit will automatically adjust the
indoor temperature according to the detected temperature. Press this button again
to close I FEEL function and "     " will disappear.

Please put the remote controller near user when this function is set. Do not put

main unit setting temperature will increase 1

, after two hours, setting temperature increa-

sed 2

, then the unit will run at this setting temperature. In Heat mode: sleep status

after run for one hour, the setting temperature will decrease 1

, after two hours, setting 

temperature will decrease 2

, then the unit will run at this setting temperature.

Sleep 2 (        ) is sleep mode 2,  air conditioner will run according to the presetted 

 group of sleep temperature curve.

Sleep 3(      )the sleep curve setting under “Sleep mode by DIY”;

(1)Under Sleep 3 (      )mode, press “Turbo” button for a long time, remote controller enters
into user individuation sleep setting status, at this time, the time of remote controller
will display “1hour”, the setting temperature “88” will display the corresponding temp-
erature of last setting sleep curve and blink (The first entering will display according to
the initial curve setting value of original factory);
(2)Adjust 

"▲"

 and "    " button, could change the corresponding setting temperature, 

after adjusted, press “Turbo” button for confirmation;
(3) At this time, 1hour will be automatically increased at the timer position on the remote 
control, (that are "2hours" or "3hours" or "8hours"), the place of setting temperature "88" 
will display the corresponding temperature of last setting sleep curve and blink;
(4) Repeat the above step (2)~(3) operation, until 8 hours temperature setting finished, 
sleep,curve setting finished, at this time, the remote controller will resume the original 
timer display; temperature display will resume to original setting temperature.

Sleep3(      ) the sleep curve setting under “Sleep mode by DIY” could be inquired:

The user could accord to sleep curve setting method to inquire the presetting sleep 
curve, 

enter into user individuation sleep setting status, but do not change the tempera-

ture, press “Turbo” button directly for confirmation. 
Note: In the above presetting or enquiry procedure, if there is no button passed within 
10s, the sleep curve setting status will be automatically quit and resume to display the 
original displaying. In the presetting or enquiry procedure, press "ON/OFF" button, 
"Mode" button, "Timer" button or "Sleep" button, the sleep curve setting or enquiry 
status will quit correspondingly.  

  

SLEEP button

8

Press this button, can select Sleep 1 (      ), Sleep 2 (      ), Sleep 3 (      ) and cancel

the Sleep function, circulate between these. After electrified, Sleep Cancel is defaulted.
Sleep 1(       )is Sleep mode 1, in Cool mode; sleep status after run for one hour, the 

Содержание RS-S9KE

Страница 1: ...i a e p y t t i l p s c i n o s a R g n i s a h c r u p r o f u o y k n a h T manual carefully before installation and well keep this manual for your future reference Some figures in this manual may...

Страница 2: ......

Страница 3: ...ote controller 9 Function introduction for combination buttons 15 Operation guide 17 Replacement of batteries in remote controller 17 Emergency operation 18 Maintenance Clean and maintenance 18 Malfun...

Страница 4: ...jury or property loss is caused by the following reasons Indicates a hazardous situation that if not avoided will result in death or serious injury Indicates a hazardous situation that if not avoided...

Страница 5: ...ildren without supervision Do not connect air conditioner to multi purpose socket Otherwise it may cause fire hazard Do disconnect power supply when cleaning air conditioner Otherwise it may cause ele...

Страница 6: ...amage Precautions WARNING conditioner and disconnect power immediately and then If the air conditioner operates under abnormal conditions it may cause malfunction electric shock or fire hazard Do not...

Страница 7: ...ect the live wire neutral wire and any work related to electricity and safety Be sure to cut off the power supply before proceeding Including an circuit breaker with suitable capacity please Air Condi...

Страница 8: ...e connected by a professional national wiring regulations local requirement by authorized personnel only Precautions WARNING wire which can t be used for other purposes The grounding resistance should...

Страница 9: ...ls or plants If it is unavoidable please add the fence for safety purpose Select a location which is out of reach for children and reachable after finishing installation For the air conditioner with p...

Страница 10: ...lease refer to actual products Parts name Indoor Unit Outdoor Unit air inlet panel aux button horizontal louver air outlet remote controller Actual product may be different from above graphics please...

Страница 11: ...Display content or position may be different from above graphics please refer to actual products Display For some models heating indicator temp indicator cooling indicator power indicator receiver win...

Страница 12: ...button Not applicable 10 TIMER ON TIMER OFF button 8 SLEEP button 5 button Send signal Turbo mode Ventilation function Not applicable 8 heating function Not applicable Set temperature Set time X FAN...

Страница 13: ...9 F F F Introduction for buttons on remote controller Note i 1 2 AU FAN RY A Specific functions are not applicable to this model Only applicable to heat pump model specific If...

Страница 14: ...ter setting is nished temperature indica tor on indoor unit will change accordingly Temperature can t be adjusted under This button is used for setting Fan Speed in the sequence that goes from AUTO to...

Страница 15: ...available When air conditioner receives this signal the air conditioner will blow fan automatically Press this button continuously more than 2s the main unit will swing back and forth from up to down...

Страница 16: ...itial curve setting value of original factory 2 Adjust and button could change the corresponding setting temperature after adjusted press Turbo button for confirmation 3 At this time 1hour will be aut...

Страница 17: ...to avoid detecting inaccurate ambient temperature When I FEEL function is turned on the remote controller should be put within the area where indoor unit can receive the signal sent by the remote con...

Страница 18: ...or specific models When quiet function is selected Under cooling mode indoor fan operates at notch 4 speed 10 minutes later or when indoor ambient temperature 28 indoor fan will operate at notch 2 spe...

Страница 19: ...imultaneously Press the button for the fourth time to start air purification function LCD display Press this button again to repeat the operation above 16 TEMP button By pressing this button you can s...

Страница 20: ...splay 46 heating 8 heating function Not applicable Under heating mode press TEMP and CLOCK buttons simultaneously to start up or turn off 8 heating function When this function is started up and 8 will...

Страница 21: ...AAA 1 5V dry batteries and make sure the position of polar and polar are correct 3 Reinstall the cover of battery box signal sender battery Cover of battery box remove reinstall During operation point...

Страница 22: ...Turn off the air conditioner and disconnect the power before cleaning the air conditioner to avoid electric shock Do not use volatile liquid to clean the air conditioner Do not use liquid or corrosiv...

Страница 23: ...pen panel Pull out the panel to a certain Use dust catcher or water to the water below 45 to clean it and then put it in a shady and cool place to dry panel cover tightly operation environment clean f...

Страница 24: ...pipe is damaged 1 Disconnect power supply 3 Check whether mounting bracket for outdoor unit is damaged or corroded If yes please contact dealer Notice for disposal 1 Many packing materials are recycl...

Страница 25: ...oom Pull out the plug Reinsert the plug after about 3min and then turn on the unit again Signal receiving range is 8m Remove obstacles Select proper angle and point the remote controller at the re cei...

Страница 26: ...r temperature and hum idity is high Because indoor air is cooled rapidly After a while indoor temperature and humidity will be decrease and mist will disappear Phenomenon Check items Solution Set temp...

Страница 27: ...door unit has vapor Heating mode is turned on Only apply to heat pump model During defrosting under he ating mode it may generate vapor which is a normal phenomenon Water owing noise Air conditioner i...

Страница 28: ...ng the unit If not please When below phenomenon occurs please turn off air conditioner and discon for service Power cord is overheating or damaged There s abnormal sound during operation Air switch tr...

Страница 29: ...east 50cm At least 30cm At least 300cm At least 200cm Space to the obstruction Space to the obstruction Space to the obstruction Space to the ceiling Space to the obstruction Space to the obstruction...

Страница 30: ...y make sure that liquid valve and gas valve are fully closed and power is disconnected before detaching the connection pipe If compressor starts running when stop valve is open and connection pipe is...

Страница 31: ...of installation dimension diagram Select a location which is out of reach for children and far away from animals or plants If it is unavoidable please add the fence for safety purpose 5 27 Tools for i...

Страница 32: ...ccordance with national wiring regulations grounding with specialized grounding device by a professional Please make sure it is always grounded effectively otherwise it may cause electric shock 2 The...

Страница 33: ...ne choosing installation location rm it with the client 1 Choose the position of piping hole according to the direction of outlet pipe The position of piping hole should be a little lower than the wal...

Страница 34: ...ith torque wrench 2 When select leading out the pipe from left or right please cut off the corresponding hole on the bottom case cut off the hole left right 1 The pipe can be led out in the direction...

Страница 35: ...55 60 65 70 75 15 20 insulating pipe 1 Connect the drain hose to the outlet pipe of indoor unit 2 Bind the joint with tape outlet pipe drain hose drain hose tape outlet pipe drain hose insulating pip...

Страница 36: ...without plug an air switch must be installed in the line 32 cable cross hole Remove the wire clip connect the power connection wire to the wiring terminal with wire clip Note power connection wire Al...

Страница 37: ...parately at the end Note The power cord and control wire can t be crossed or winding The drain hose should be bound at the bottom drain hose band connection pipe indoor power cord Step nine hang the i...

Страница 38: ...ded for the unit with cooling capacity of 6000W 8000W 8 expansion screws are needed for the unit with cooling capacity of 10000W 16000W 10 expansion screws are needed 1 2 2 Place the outdoor unit on t...

Страница 39: ...with hand 4 Tighten the union nut with torque wrench by referring to the sheet below gas pipe liquid pipe liquid valve gas valve union nut pipe joint Hex nut diameter Tightening torque N m 6 9 52 12...

Страница 40: ...e outlet pipe hole of indoor unit Slant the drain hose slightly dow nwards The drain hose can t be The water outlet can t be placed in water in order to drain smoothly Installation of outdoor unit U s...

Страница 41: ...erant charging vent 2 Connect the charging hose of piezometer to the refri gerant charging vent of gas valve and then connect the other charging hose to the vacuum pump 3 Open the piezometer com plete...

Страница 42: ...ts Is there any obstruction in the air inlet Is the inlet and outlet of piping hole been covered and outlet heating capacity The dust and sundries caused during installation are removed It may cause m...

Страница 43: ...wn in the table The additional refrigerant charging amount per meter is different according to the diameter of liquid pipe See the following sheet Additional refrigerant charging amount prolonged leng...

Страница 44: ...4a Diameter of connection pipe Liquid pipe mm Gas pipe mm 6 6 or 9 52 12 16 19 22 2 9 52 or 12 16 or 19 19 or 22 2 25 4 or 31 8 _ _ Cooling only g m Cooling and heating g m 15 15 30 60 250 250 350 350...

Страница 45: ...n suitable insulating pipe D Put on the union nut Remove the union nut on the indoor connection pipe and outdoor valve install the union nut on the pipe union pipe pipe E Expand the port Expand the po...

Страница 46: ......

Страница 47: ......

Страница 48: ...6129935346 RSE0420...

Отзывы: