background image

36

How to retrieve error codes

If the unit stops and the TIMER indicator blinks, use the remote control to retrieve the error code.

ON

OFF

SET

TIMER

CANCEL

ON

OFF

SET

TIMER

CANCEL

Press for 
5 seconds

Press for 5 
seconds to 
quit checking

Press until you hear beep 
sound, then write down the 
error code

Turn the unit off and 
inform the error code to an 
authorised dealer.

2

1

3

4

• For certain errors, you may restart the unit for limited operation if there are 4 beeps when operation starts.

Troubleshooting

Diagnostic 

display

Abnormality/Protection 

control

H 00

No memory of failure

H 11

Indoor/outdoor abnormal 

communication

H 12

Indoor unit capacity unmatched

H 14

Indoor intake air temperature sensor 

abnormality

H 15

Outdoor compressor temperature 

sensor abnormality

H 16

Outdoor current transformer (CT) 

abnormality

H 17

Outdoor suction temperature sensor 

abnormality

H 19

Indoor fan motor mechanism lock

H 21

Indoor 

fl

 oat switch operation 

abnormality

H 23

Indoor heat exchanger temperature 

sensor 1 abnormality

H 24

Indoor heat exchanger temperature 

sensor 2 abnormality

H 25

Indoor ion device abnormality

H 26

Minus ION abnormality

H 27

Outdoor air temperature sensor 

abnormality

H 28

Outdoor heat exchanger temperature 

sensor 1 abnormality

H 30

Outdoor discharge pipe temperature 

sensor abnormality

H 31

Abnormal swimming pool sensor

H 32

Outdoor heat exchanger temperature 

sensor 2 abnormality

H 33

Indoor/outdoor misconnection 

abnormality

H 34

Outdoor heat sink temperature sensor 

abnormality

H 35

Indoor/outdoor water adverse current 

abnormality

H 36

Outdoor gas pipe temperature 

sensor abnormality

H 37

Outdoor liquid pipe temperature 

sensor abnormality

H 38

Indoor/outdoor mismatch (brand code)

H 39

Abnormal indoor operating unit or 

standby units

Diagnostic 

display

Abnormality/Protection 

control

H 41

Abnormal wiring or piping connection

H 50

Ventilation fan motor locked

H 51

Ventilation fan motor locked

H 52

Left-right limit switch 

fi

 xing 

abnormality

H 58

Indoor gas sensor abnormality

H 59

Eco sensor abnormality

H 64

Outdoor high pressure sensor 

abnormality

H 67

nanoe abnormality

H 70

Light sensor abnormality

H 71

DC cooling fan inside control board 

abnormality

H 72

Abnormality tank temperature sensor

H 85

Abnormal communication between 

indoor & wireless LAN module

H 97

Outdoor fan motor mechanism lock

H 98

Indoor high pressure protection

H 99

Indoor operating unit freeze protection

F 11

4-way valve switching abnormality

F 16

Total running current protection

F 17

Indoor standby units freezing 

abnormality

F 18

Dry circuit blocked abnormality

F 87

Control box overheat protection

F 90

Power factor correction (PFC)

circuit protection

F 91

Refrigeration cycle abnormality

F 93

Outdoor compressor abnormal 

revolution

F 94

Compressor discharge pressure

overshoot protection

F 95

Outdoor cooling high pressure 

protection

F 96

Power transistor module overheating 

protection

F 97

Compressor overheating protection

F 98

Total running current protection

F 99

Outdoor direct current (DC) peak 

detection

* Some error code may not be applicable to your model. Consult an authorised dealer for clari

fi

 cation.

Содержание RS-RZ9YK

Страница 1: ...ing the unit please read these operating instructions thoroughly and keep them for future reference Before installation the installer should Read the Installation Instructions then request the custome...

Страница 2: ...EN 2 1 1 2 AAA R03 3 8 A 1 5 12 am pm 24 2 ON OFF SET TIMER CANCEL OFF ON AIR SWING TEMP OFF ON MODE SLEEP FAN SPEED QUIET POWERFUL ECO ON OFF TIMER CANCEL AIR SWING SLEEP FAN SPEED QUIET POWERFUL EC...

Страница 3: ...3 B 2 DRY AUTO HEAT COOL 1 POWER ON 3 TEMP UP TEMP DOWN 16 0 C 30 0 C 60 F 86 F 10 C F 4 11 12 13 14 15 16 18 19 AAA R03 2 2 Rasonic...

Страница 4: ...4...

Страница 5: ...5 ON Ni Cd ELCB RCD ELCB BS...

Страница 6: ...6 nanoe G R32 Amin m Amin m A R32 R410A R22 R32 R22 R32 R22 R32 R410A R32 R410A R32 R410A R22 R32 R410A 1 2 R32 R410A AHU a b c d...

Страница 7: ...7 e f g h i j 5 0 25 1 04 MPa 4 15 MPa 1 A Amin m 12 2 2 1 2 2 2 2 2 8 2 2...

Страница 8: ...8 2 3 2 4 CO2 2 5 2 6 2 7 2 8...

Страница 9: ...9 6 7 5 1 04 MPa 4 15 MPa 0 25 LFL 25 8 3 4 5...

Страница 10: ...10 10 a b c d e f g h 80 i j k 11 8 OFN OFN OFN OFN 9 OFN 7...

Страница 11: ...11 12...

Страница 12: ...FAN QUIET FAN SPEED QUIET POWERFUL 20 ECO POWERFUL ECO POWERFUL ECO OFF ON OFF ON nanoe G ON OFF AIR SWING nanoe G POWER TIMER nanoe G ECO ON OFF SET TIMER CANCEL OFF ON AIR SWING TEMP OFF ON MODE SL...

Страница 13: ...EP POWERFUL ECO FAN SPEED QUIET POWERFUL ECO POWERFUL QUIET FAN SPEED 0 5 1 2 3 4 5 6 7 8 9 OFF 0 0h SLEEP ON OFF SET TIMER CANCEL 1 2 3 1 TIMER ON TIMER OFF 22 00 OFF OFF 2 3 SET ON OFF CANCEL ON OFF...

Страница 14: ...EAT 20 0 C 24 0 C 68 F 75 F COOL 26 0 C 28 0 C 79 F 82 F COOL DRY HEAT AUTO COOL HEAT DRY C F DBT WBT DBT WBT COOL 32 89 6 23 73 4 46 114 8 26 78 8 16 60 8 11 51 8 16 60 8 11 51 8 HEAT 30 86 0 24 75 2...

Страница 15: ...15 AUTO OFF ON nanoe G H 99 pH 7 40 C 104 F nanoeTM G 2 2 nanoe G 1 2 2 AUTO OFF ON nanoe G 1 3 4...

Страница 16: ...16 POWER TIMER ON 30 TIMER ON 30 nanoe G HEAT COOL nanoe G nanoe G...

Страница 17: ...17 AUTO OFF ON 1 2 AUTO 3 COOL 4 2 HEAT 5 5 AUTO OFF ON COOL HEAT 15 COOL 8 C 14 4 F HEAT 14 C 25 2 F HEAT 2 3...

Страница 18: ...2 H 14 H 15 H 16 CT H 17 H 19 H 21 H 23 1 H 24 2 H 25 H 26 ION H 27 H 28 1 H 30 H 31 H 32 2 H 33 H 34 H 35 H 36 H 37 H 38 H 39 H 41 H 50 H 51 H 52 H 58 H 59 H 64 H 67 nanoe H 70 H 71 H 72 H 85 H 97 H...

Страница 19: ...19 Pb...

Страница 20: ...oximately 5 seconds to show the time as 12 hour am pm or 24 hour 2 Press to confirm Use the remote control within 8 m from the remote control receiver on the indoor unit Provides maximum comfort and c...

Страница 21: ...ately 10 seconds to show the temperature as C or F Table of Contents Safety Precautions 22 29 How to Use 30 31 To Learn More 32 Cleaning the Air Conditioner 33 Troubleshooting 34 36 Information 37 Acc...

Страница 22: ...plosive or flammable atmosphere Failure to do so could result in fire Do not insert your fingers or other objects into the air conditioner indoor or outdoor unit rotating parts may cause injury Do not...

Страница 23: ...ic shock nanoe G generator Do not touch the sharp pin which may cause injury Power supply Do not use a modified cord joint cord extension cord or unspecified cord to prevent overheating and fire To pr...

Страница 24: ...al the opening by pinching taping etc Handling of R32 is similar to R410A Operation maintenance repairing and refrigerant recovery should be carried out by trained and certified personnel in the use o...

Страница 25: ...the precautions in 12 and comply with national regulations Always contact to local municipal offices for proper handling 2 Servicing 2 1 Service personnel The system is inspected regularly supervised...

Страница 26: ...ernally into the atmosphere 2 7 Checks to the refrigerating equipment Where electrical components are being changed they shall be fit for the purpose and to the correct specification At all times the...

Страница 27: ...the atmosphere from a leak 5 Cabling Check that cabling will not be subject to wear corrosion excessive pressure vibration sharp edges or any other adverse environmental effects The check shall also t...

Страница 28: ...minimize the amount of refrigerant contained in them Cylinders shall be kept in an appropriate position according to the instructions Ensure that the refrigerating system is earthed prior to charging...

Страница 29: ...employed Ensure that the correct number of cylinders for holding the total system charge are available All cylinders to be used are designated for the recovered refrigerant and labelled for that refri...

Страница 30: ...matically when the unit is turned on with OFF ON OFF ON This operation can be turned ON or OFF manually by pressing This operation can be activated even when the unit is turned off In this condition t...

Страница 31: ...operation has the priority over OFF timer This operation can be cancelled by pressing the respective button until the sleep timer reaches 0 0h SLEEP How to Use To set the timer ON OFF SET TIMER CANCEL...

Страница 32: ...fixed at middle position setting Once the temperature is achieved the horizontal flap swings up down automatically In HEAT mode If AUTO is set the horizontal flap is fixed at the predetermined positi...

Страница 33: ...Once every 2 weeks Wash rinse the filters gently with water to avoid damaging the surface Dry the filters thoroughly under a shade away from fire or direct sunlight Replace any damaged filters Remove...

Страница 34: ...ation condensation occurs on cold pipes and the condensed water may drip from the outdoor unit Discoloration of some plastic parts Discoloration is subjected to the types of materials used in plastic...

Страница 35: ...r The remote control is missing or a malfunction has occurred above After 15 minutes of operation it is normal to have the following temperature difference between the air inlet and outlet vents COOL...

Страница 36: ...heat sink temperature sensor abnormality H 35 Indoor outdoor water adverse current abnormality H 36 Outdoor gas pipe temperature sensor abnormality H 37 Outdoor liquid pipe temperature sensor abnorma...

Страница 37: ...ght be used in combination with a chemical symbol In this case it complies with the requirement set by the Directive for the chemical involved WARNING This symbol shows that this equipment uses a flam...

Страница 38: ...Memo...

Страница 39: ...Memo...

Страница 40: ...Printed in Malaysia Panasonic Corporation 1006 Oaza Kadoma Kadoma City Osaka 571 8501 Japan Website http www panasonic com Panasonic Corporation 2022 ACXF55 32290 SS0122 0...

Отзывы: