18
To learn more...
Operation mode
AUTO
:
During operation mode selection the POWER indicator blinks.
• Unit selects the operation mode according to the room temperature.
• Once AUTO mode is selected, the unit will operate at the standard setting temperature.
Room temperature
Operation mode
Standard setting temperature
23 °C / 73 °F & above
COOL
25 °C / 77 °F
Below 23 °C / 73 °F
DRY
22 °C / 72 °F
• Press
for “HI” to +2 °C / +4 °F or
for “LO” to -2 °C / -4 °F to the standard setting
temperature.
COOL
:
Provides ef
fi
cient comfort cooling to suit your needs.
DRY
:
Unit operates at low fan speed to give a gentle cooling operation.
Energy saving temperature setting
Operating the unit within the recommended temperature range may save energy.
COOL :
26 °C ~ 28 °C / 79 °F ~ 82 °F.
Air
fl
ow direction
In COOL/DRY mode:
If AUTO is set, the
fl
aps swings up/down automatically.
Auto restart control
If power is resumed after a power failure, the operation will restart automatically after a
period of time with previous operation mode and air
fl
ow direction.
• This control is not applicable when TIMER is set.
Operating conditions
Use this air conditioner in the temperature range indicated in the table.
Temperature °C (°F)
Indoor
Outdoor
DBT
WBT
DBT
WBT
COOL
Max.
32 (89.6)
23 (73.4)
43 (109.4)
26 (78.8)
Min.
16 (60.8)
11 (51.8)
16 (60.8)
11 (51.8)
DBT: Dry bulb temperature, WBT: Wet bulb temperature