ACXF55-32940

NOISE CONSIDERATION

Select an installation location that can support the weight of the air

conditioner and one that will not cause increased operating noise 

and vibration.

Ensure that when installed, airflow and noise from the rear side of the 

unit (outdoor) do not disturb neighbouring elements.
Obstacles placed in front of the air outlet on the rear side of the unit 

(outdoor), or covers placed over it will cause excessive noise and 

deterioration in performance.

TRANSFERRING

Repositioning or transfer of the air conditioner due to renovation or moving requires an additional service

charge. Please consult your dealer before moving.

AIR CONDITIONER OPERATION

OPERATING THE UNIT

Start operation by pressing OFF/ON.

The operation will turn on and the display panel will light up.

To stop the operation, press the OFF/ON again.

The unit will stop operating and the display panel light will turn off.

CARE AND MAINTENANCE

Clean the cabinet, front grille with mild soap or detergent and lukewarm water.

NOTE: Do not dry the front panel or the air filter in direct sunlight. 

            (Exposure to direct sunlight may discolour deform the panel.)

If the air filter becomes clogged with dust, the cooling capacity will drop, and 6% of the electricity used to 

operate the air conditioner will be wasted.

If the unit is extremely dirty, heat transfer is less Efficient and the unit may not cool effectively. Contact 

Shun Hing Electric Service Center Ltd. for an annual check. (Annual check is not covered by the warranty.)

Do not clean with benzene, thinner, scouring powder or cloth soaked in caustic chemicals.

The filter can be easily cleaned using a vacuum cleaner. Vacuum the front of the filter and then wash the 

rear with water. If it is badly spoiled, wash with a mild household detergent.

The front intake grille can be easily removed for cleaning purposes (refer to Remove the front intake 

grille procedures). Gently wash it with water and a sponge.

PRE-SEASON INSPECTION

Is the discharged air cold?

Are the air intake and outlet vanes of the indoor and outdoor side obstructed?

Are the remote control batteries weak?

After 15 minutes of operation, it is normal for the temperature difference between intake and outlet air 

to be more than 8

°

C for cooling.

RECOMMENDED INSPECTION

BEFORE CALLING FOR SERVICE

Usage over several seasons will reduce performance as the unit becomes dirty. A dirty unit may produce foul 

odours and dust may clog the dehumidifying drainage. Seasonal inspection is recommended in addition to 

regular cleaning. Consult Shun Hing Electric Service Centre Ltd.,

Check the following points before calling for repairs or service. 

If the malfunction persists, please contact Shun Hing Electric Service Centre Ltd.,

OFTH0811-00

Printed in Philippines

5

6

HELPFUL INFORMATION & ENERGY SAVING HINTS

HELPFUL INFORMATION

ENERGY SAVING HINTS

Auto Restart Control

Timer Setting

Operation will automatically resume under the previous operation mode.

If the unit was set to TIMER mode or SLEEP mode, operation will not resume automatically.

When power failure occurs, the timer setting is cancelled. Once power returns, reset timer.

Your air conditioner’  s cooling capacity should match your room size.

For health reason do not overcool your room.

Avoid direct sunlight and heat

Keeping ventilation set to CLOSE closed keeps cool air in and hor air out.

Clean the air filter every 2 weeks. Regular cleaning of the air filter preserves efficiency.

3UHVV7(03ŸRUźWRVHWWKHGLVSOD\WHPSHUDWXUH

The temperature can be set between 16°C and 30°C.

Recommended  temperature: 26°C~28°C

NOTES:

SETTING DISPLAY TEMPERATURE

The previous set temperature will be stored and displayed when the air-con is ON.

Display

will

change 

according

to the

setting.

TEMP

SELECTING OPERATION MODE

Press MODE to select the desired operation.

A  “beep” sound will indicate changing setting.

COOL mode

To set room temperature to your preference of cooling comfort.

FAN mode

To provide air circulation without cooling the room. During Fan 

operation, temperature setting cannot be selected.

DRY mode

Mild air-conditioning operation for the purpose of reducing room humidity

(The intermittent operation of the air conditioner has achieved the purpose of dehumidification)

MODE

COOL

DRY

FAN

SELECTING FAN SPEED

Press FAN SPEED to choose the speed level of the fan.

A “beep” sound will indicate changing setting.

NOTE:

The latest fan speed setting will be memorized and the indicator will light up the next time

the unit is turned on.

FAN SPEED

POWERFUL OPERATION

To obtain set temperature quickly:

Press POWERFUL,The indicator will light up. 

To cancel this operation, press once more.

After POWERFUL is selected, the operation will go on for 15 minutes, after that it will shift

back to previous operation mode.

NOTE:

Sound emitted by the unit will be increased during POWERFUL operation due to increased of 

air volume.

Cooling

-3 C lower than set temperature

(lowest limit 16 C)

Super High Fan Speed

ADJUSTING HORIZONTAL AIRFLOW DIRECTION

Press to select AIR SWING.

The air circulation will automatically move the vertical louver

left and right for better air distribution around the room.
NOTE:

Using your hands to adjust the direction may cause the 

louvres to malfunction. If this happens, stop operation 

immediately and restart.

AIR SWING

AUTO

When the air conditioner is ON:

Press the TIMER-ON button to set the timer.

Press the same button until the preferred hour of operation is reached.

(The TIMER indicator light will blink to await for setting)

Press TIMER SET button to complete the setting. At this time, the TIMER indicator light is steady

 instead of blinking. 

NOTE: 

it is unavailable to set ON TIMER and OFF TIMER simultaneously.

The timer figure will change according to the time remaining.

SETTING THE OFF TIMER

SLEEP MODE SETTING

Cooling mode

!

The temperature adjustment in dehumidification mode is invalid

The air conditioner will gradually increase the temperature during sleeping time. When the set room temperature is reached, 

it will maintain the set temperature for an hour and will shift 0.5°C up. The 0.5°C up will be maintained for an hour and then will 

shift 0.5°C up for a total of 1°C up will be maintained.

NOTE: The automatic shift of temperature (Max 1°C) is not indicated on the display panel. 

Press SLEEP button to start Sleep mode. 

Note: If the TIMER button is pressed after selecting TIMER OFF, there will Can set off timer.

SLEEP

CANCEL OFF TIMER SETTING

Press the remote CANCEL button to cancel the timer setting. The TIMER indicator light 

will turn off. However the temperature remains displayed.

CANCEL

When the air conditioner is OFF:

Press the TIMER-OFF button to set the timer.

Press the same button until the preferred hour of operation is reached.

(The TIMER indicator light will blink to await for setting)

Press TIMER SET button to complete the setting. At this time, the TIMER indicator light is steady 

instead of blinking. 

NOTE: 

it is unavailable to set ON TIMER and OFF TIMER simultaneously.

The timer figure will change according to the time remaining.

SETTING THE ON TIMER

CANCEL TIMER SETTING DURING ON TIMER

Press the OFF/ON or CANCEL button to cancel the timer setting. 

Note for the battery symbol (bottom two symbol examples):

This symbol might be used in combination with a chemical symbol. In this case it complies with the 

requirement set by the Directive for the chemical involved.

To call Shun Hing Electric Service Centre Ltd. IMMEDIATELY 

Turn off the power and contact Shun Hing Electric Service Centre Ltd. 

as soon as any of the following events occur.

The circuit breaker frequently trips or the fuse blows regularly.

If water or foreign objects have accidentally entered the air conditioner.

If there is abnormal sound during operation.

NOTE:

1. The enclosure opposing the room side is splash proof (IPX4).

2. Do not install this appliance in a laundry room or other locations where water may drip from the ceiling, etc.

3. If the supply cord is damaged or need to be replaced, it must be replaced by the manufacturer or its service 

    agent or a similarly qualified person in order to avoid a hazard.

Green Yellow: Earth       Blue: Neutral      Brown: Live

“As the coulours of the wires in the mains lead of this appliance my not correspond with the coloured markings identifying the terminals in your plug,
proceed as follows:
The wires which is coloured green and yellow must be connected to the terminal in the plug which is marked by the letter E or by the safety earth
symbol       or coloured green or green and yellow. The wire which is coloured blue must be connected to the terminal which is marked with letter N 
or coloured black. The wire which is coloured brown must be connected to the terminal which is marked with letter L or colour red.”
(NOTE: Replacement of installation of power plug shall be performed only by authorized/qualified personnel.)
 

IMPORTANT

* The wires in this mains lead are coloured in accordance with the following code:
    

If the unit is too noisy during operation.

The following sounds are normal during operation:

A low humming sound indicating that the unit is operating.

A splashing sound indicating condensation in the 

condenser coil.If you hear other noises, please consult

 Shun Hing Electric Service Centre Ltd.,

A flowing sound due to circulation of the refrigerant when

the compressor is turned on.

A soft clicking sound when the compressor turns on and off.

Condition

1

Information for Users on Collection and Disposal of Old Equipment and used Batteries

Condition

2

If the unit does not operate.

The main power cord is not plugged in.

The main circuit breaker has tripped.

Condition

3

If the unit does not cool properly.

The room is too big for the unit’  s capacity.

The ventilation lever is set to OPEN

The air circulation is impeded by curtains or furniture.

After 15 minutes of operation, it is normal for the temperature 

difference between intake and outlet air to be more than 8

°

for cooling.

[Information on Disposal in other Countries outside the European Union]

These symbols are only valid in the European Union. If you wish to discard these items, please contact 

your local authorities or dealer and ask for the correct method of disposal.

If water drips inside the room.

Condition

5

The unit is tilted inward. To rectify this, tilt the unit slightly outward.

Mount the optional drain pan if you prefer.

The drain pan may be blocked.

Condition

6

Squeaking noise during operation,

Squeaking noise after shutting down

(This is due to the expansion or contraction of the model

due to temperature changes)

If water drips off the rear of the unit.

Humidity is high.

Condensed water is overflowing.

To rectify the problem, mount an optional drain pan to the unit.

Condition

4

û7KHDLUFRQGLWLRQHUEORZVRXWFROGPLVW\

DLUDQGWKHLQGRRUDLUFRPHVLQWRFRQWDFW

ZLWKWKHFROGDLUEORZQRXWRIORZ

WHPSHUDWXUHWRSURGXFHPLVW\DLU

û7KHUHVHHPVWREHDVRXQGRIUXQQLQJ

ZDWHU7KLVLVWKHVRXQGRIWKH

UHIULJHUDQWIORZLQJLQVLGHWKHDLU

FRQGLWLRQHU

û2FFDVLRQDOO\WKHUHLVWKHVRXQGRI*,*$

WKHH[SDQVLRQ

DQGFRQWUDFWLRQ

RIWKHIURQWOHDI

ZLQGRZGXHWR

WHPSHUDWXUH

FKDQJHV

Vertical 

louver

Отзывы: