background image

If wireless remote controller is lost, open the surface panel and operate manually. 

Note:

-"OPEN" position,the ventilation door

opens to allow air,smoke or odors to

be expelled from the room.

-"CLOSE" position,the ventilation door

is closed and the air will be circulated

inside the room and conditioned.

VENTILATION LEVER

Ventilation Lever

When the slider at the:

When the slider at the:

Remote control panel

1

POWER  BUTTON

Operation starts when pressing this button, and stops

when pressing this button again.

2

FAN SPEED BUTTON

Select the fan speed HIGH, MID, LOW and AUTO in sequence.

3

Press the    keypad also to increase the selected time

in 1 hour increments,and Press the     keypad  to 

decrease the selected time in 1 hour decrements,The 

time seting range is from 0~24 hours.

TEMP/TIMER BUTTON
Press the

keypad to increase the set (operating)

temperature of the unit.and Press the    keypad to 

decrease the set (operating) temperature of the unit.

The temperature seting range is from 16~30

MODE BUTTON

Select the operation mode, AUTO, HEAT, COOL, FAN,

DRY (for reverse cycle model) or AUTO,COOL,FAN, DRY

 (for cooling only model).

5

SIGNAL  RECEIVER

6

SWING BUTTON

Activate the automatic air swing function.

FILTER  BUTTON

This feature is a reminder to clean the Air Filter (See
Care and Cleaning) for more efficient operation and
cooling. The LED (light) will illuminate after 250 hours

"Check Filter" button and the light will go off.

of operation. To reset after cleaning the filter, press the

15

Содержание RC-X7

Страница 1: ...nditioner Thank you for purchasing Rasonic window type air conditioner Please read the user manual carefully before installation and well keep user manual for your later reference Model RC X9 RC X7 OPERATING INSTRUCTIONS ...

Страница 2: ...enance 3 3 4 7 2 Precautions 1 After service 20 This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible fortheir safety Children should be supervised to ensure that they do not play with ...

Страница 3: ...at if not avoided could result in death or serious injury Indicates a hazardous situation that if not avoided may result in minor or moderate injury Indicates important but not hazard related information used to indicate risk of property damage Indicates a hazard that would be assigned a signal word WARNING or CAUTION WARNING CAUTION DANGER NOTICE ...

Страница 4: ... circuit when installing the air conditioner break Children shall not play with the appliance Cleaning and user maintenance shall not be made by children without supervision The air conditioner should be installed in accordance with national wiring regulation Air Conditioner should be properly grounded Incorrect grounding may cause electric shock hazard broken injury or damage personal injury Do n...

Страница 5: ...ibrary and laboratory and so on Room temp Spring Summer Autumn Wind direction Winter Cooling in summer In hot summer Air conditioner can cool down theroom air by transferring heat out Without reducing the room temp air conditioner can dehumidify and make the room air dry and comfortable Dehumidifying in rainy or humid season Exchange fresh air Open storm door to keep the fresh air in the room Dry ...

Страница 6: ... water af ter running for so much time But this is normal Water pipe The electric components will be damaged when the voltage is too high If the voltage is too low the compressor will vibrate violently to dam age the refrigerant system and easily cause the compressor and elec tric components not work The ground must be connected Special socket must be used Furthermore the socket and wiring must co...

Страница 7: ...ous gas or other special areas please contact the seller before use Avoid a place where is possible for inflammable gas to leak out Avoid other heat sources or direct sun light Avoid a place where is easy for children to touch For window type air conditioner with remote control install in a location where is strong elec tromagnetic disturbance you should contact the seller in advance to avoid the ...

Страница 8: ...the enlargement of noise or vibration 3 Fill up sews in the cabinet with sponge or foam Installation assistance Use iron support The installation hole should be strong enough to support the air conditioner If it cannot iron sup port has to be used outdoors Iron support should be fixed on the building Shown at right figure Use sunshade board Air conditioner should avoid anything to be dropped into ...

Страница 9: ... the drain pan to the corner of the cabinet with 2 screws 4 Connect the drain hose to the outlet on the drain pan bottom 5 Slide the chassis into its original place in the cabinet Drain water for one style To get the maximum cooling efficiency the air conditioner is designed to splash the condensate on the condenser coil If the splashing sound annoys you you can provide an outside drain by using t...

Страница 10: ...able socket can t be used because poor contact of it can cause over heat or fire If the supply cord is damaged it must be replaced by the manufacturer or your dealer In fixed circuit there must be electricity leakage protection switch and leakage current is less than 30mA Air switch thermal magnetic breaker should be installed in the circuit Don t pull the power cord strongly or a qualified person...

Страница 11: ... filter behind the front intake grille Front intake grille Control panel Power cord Front grille Air inlet louver Cabinet Front grille Air inlet louver Cabinet Air filter behind the front intake grille Front intake grille Remote control panel Power cord 8 Part identification Panel outlook picture just for reference please take the real unit as standard Panel outlook picture just for reference plea...

Страница 12: ... period turn the thermostat When the thermostat control knob is set to 10 moisture may freeze onto evaporator fins and obstruct the effective cooling If this happened turn the main control knob to FAN and the thermostat control knob counter clockwise This will quickly defrost the evaporator fins so that normal cooling can be resumed CAUTION If the main control knob is turned off of changed to a fa...

Страница 13: ...ON OFF button MODE button button FAN button SWING button SLEEP button TIMER button Timer on Timer off Sending signal swing operation sleep operation lock set speed Set time Set temperature heat operation fan operation dry operation cool operation auto operation 10 Remote control operation procedure ...

Страница 14: ... set temperature Press FAN button to adjust fan speed When selecting dry mode air conditioner will operate at low fan speed under dry mode In dry mode fan speed can t be adjusted When selecting fan mode air conditioner will operate in fan mode only Then press FAN button to adjust fan speed When selecting heat mode air conditioner will operate under heat mode Then press or button to adjust set temp...

Страница 15: ...tton to set Timer Off T OFF and H icon will be blinking Within 5s press or button to adjust the time for Timer Off Pressing or button once will increase or decrease the time by 0 5h Hold or button for 2s time will change quickly Release the button after your required set time is reached Then press TIMER button to confirm it T OFF and H icon will stop blinking When unit is off press this button to ...

Страница 16: ...ontroller won t send signal Child lock function Temperature display switchover function Under OFF status press button and MODE button simultaneously can switch between C and F Operation guide 1 After putting through the power press ON OFF button on remote controller to turn on the air conditioner 2 Press MODE button to select your required mode AUTO COOL DRY FAN HEAT 3 Press or button to set your ...

Страница 17: ... Make sure positions for pole and pole are correct 3 Reinstall batteries box cover The distance between signal sender and receiving window should be no more than 8m and there should be no obstacles between them conditioner when using the remote controller Replace new batteries of the same model when replacement is required When you don t use remote controller for a long time please take out the ba...

Страница 18: ...n 1 hour increments and Press the keypad to decrease the selected time in 1 hour decrements The time seting range is from 0 24 hours 4 TEMP TIMER BUTTON Press the keypad to increase the set operating temperature of the unit and Press the keypad to decrease the set operating temperature of the unit The temperature seting range is from 16 30 MODE BUTTON Select the operation mode AUTO HEAT COOL FAN D...

Страница 19: ...n the room Air can t be discharged to the di rection of air in Make sure that the doors and win dows are tightly closed Avoid open ing doors and windows frequently to keep air conditioning in the room Clean the air filter regularly Blockages in the air filter re duce dehumidifying effects Clean the air filter at least once every two weeks Ventilate the room occasionally Since windows are kept clos...

Страница 20: ...s Do not pull out the power cord Damage to the cord may result in serious electric shocks s plastic parts will melt if exposed to excessive heat Avoid exposing the body directly to a continuous unidirectional air flow for long periods This is not recommended for health reason Select the most appropriate temperature Pay attention to adjust the tempera ture to suit the conditions Rooms occupied by i...

Страница 21: ...nlet and outlet of outdoor unit are blocked or not Let the filter dry thoroughly before reinstalling it If necessary please ask the professional personnel to clean it 2 Vacuum the filter on the dusty side to remove light dust 3 Wash the filter cleaner side up under gently flowing water to wash out accumulated dust and lint 4 If the filter is very dirty use a mild household detergent in the wash wa...

Страница 22: ...y be mixed with the smell of furniture and smoke For a noise that sounds like water flowing This is the sound of freon flowing inside the air con ditioner unit For a noise that sounds like a shower This is the sound of the dehumidifying water being processed inside the air conditioner unit Condensation occurs when the airflow from the air conditioner cools the warm room air This is to protect the ...

Страница 23: ...lowing events occur The circuit breaker frequently trips or the fuse blows regularly If water or foreign objects have accidentally entered the air conditioner If there is abnormal sound during operation Special Avowal After sale service 1 The information above has been checked our company reserves the hermeneutic power to any print errors or misunderstanding on the content 2 Any technology improve...

Страница 24: ... NEW TERRITORIES HONG KONG 電話 TEL 852 2406 5666 傳真 FAX 852 2408 0316 網址 WEBSITE www shesc com 消耗品 附件銷售熱線 CONSUMABLES ACCESSORIES SALES HOTLINE 電話 TEL 852 2406 5666 客戶服務中心 CUSTOMER SERVICE CENTRES 香港新界葵涌勝耀街2號信興中心1樓 1ST FLOOR SHUN HING CENTRE 2 SHING YIU STREET KWAI CHUNG NEW TERRITORIES HONG KONG 電話 TEL 852 2406 5439 傳真 FAX 852 2408 1389 澳門慕拉士大馬路193 199號南嶺工業大廈5樓I座 AVENIDA DE VENCESLAU DE MORAIS NO ...

Отзывы: