When installing air conditioner at glass window
or thin partition, fix the vertical and side supporting
bar to the concrete wall in order to support the weight
of the air-conditioner and reduce the vibration that is
being transferred to the glass window or thin partition.
This can minimize the noise problem caused by
improper installation.
ACXF55-32950
Do not use the unit for other purposes, than its intended use.
Do not remove the power plug by pulling the cord.
Do not block the air intake and outlet vanes.
Do not splash or direct water at the unit.
Do not expose the unit to direct sunlight during operation.
Do not operate the unit without the air filter installed
or when the front intake grille has been removed.
Do not place any objects on the unit.
Do not operate any combustion equipment near the unit’s
air flow area.
Do not sit or step on the unit, you may fall down accidentally.
Do not touch the sharp aluminium fin, sharp parts may
cause injury.
Do not use means to accelerate the defrosting process or to
clean, other than those recommended by manufacturer.
Plug in properly before operating and use a specified power cord.
If abnormal conditions (burnt smell, etc.) occur, switch off and
remove the power plug.
Confirm to authorized dealer or specialist on usage of specified
refrigerant type. Using of refrigerant other than the specified
may cause product damage, burst and injury etc.
This appliance is not Intended for use by persons (including children)
with reduced physical, sensory or mental capabilities, or lack of
experience and knowledge, unless they have been given super-
vision or instruction concerning use of the appliance by a person
responsible for their safety. Children should be supervised to
ensure that they do not play with the appliance.
Switch off the breaker and unplug the unit from the socket
if the unit will not be operated for a long period.
Pay attention to any damages on the unit caused by
extensive usage.
Ventilate the room occasionally where the unit is installed.
Unplug the power cord when cleaning the unit.
Main Control Panel
OPERATION PRECAUTION
MAIN UNIT
This sign warns of risk of
death or serious injury.
This sign warns of risk of injury
or damage to property.
Do not modify the length of power cord or use an extension cord.
Do not touch or operate with wet hands.
Do not modify or damage the cord.
Do not turn on the unit by inserting the power plug.
Do not switch off the unit by pulling out the power plug.
Avoid an extended period of direct airflow.
Do not Insert your fingers or other objects into the unit, rotating
parts may cause injury.
Do not try to repair the unit yourself.
PARTS IDENTIFICATION
2
CHOOSING THE INSTALLATION LOCATION
PREPARATIONS BEFORE INSTALLATION
CAUTION POINT DURING INSTALLATION
REMOVAL OF FRONT GRILLE
AIR CONDITIONER OPERATION
3
AIR CONDITIONER INSTALLATION
4
Air Swing Switch
(Airflow direction adjustment Side-to-Side)
To obtain a fix airflow direction, set the air swing switch to “ON” for the
vanes to swing from side to side until the desired flow direction is reached,
then switch it to “OFF”.
For continuous side-to-side air cirulation set the air swing switch to “ON”.
OPERATING INSTRUCTIONS
ROOM AIR CONDITIONER
ENGLISH
RC-N921J
Main Control Knob
Air Swing Switch
OFF Stops the operation of Air Swing.
ON Air Swing is in operation.
(Only for LOW COOL and
HIGH COOL operation.)
Low fan speed operation
(without cooling)
Low fan speed with
cooling operation
High fan speed with
cooling operation
High fan speed operation
(without cooling)
“OFF”
Stops all operation
Main Control Knob
Turn the thermostat control knob as shown:
Main Control Knob
Set to LOW COOL or HIGH COOL as desired.
(FAN setting operates the fan only.)
Caution: If the main control knob is turned off or changed to a fan setting
from a cooling operation setting, WAIT at least 3 minutes before
resetting to cooling operation.
1
Thermostat Control Knob
Set the thermostat control knob to your desired setting. (Usually 6 - 7 is
recommended). If the room temperature is not as desired after a reasonable
period of time, turn the thermostat control knob clockwise to cool the room
more or counter clockwise to cool the room less.
When the thermostat control knob is set to 10, moisture may freeze on
the evaporator fins and prevent effective cooling. If this happens, turn
the Main Control Knob to HIGH FAN and the Thermostat Control Knob
counter-clockwise. This will quickly defrost the evaporator fins to resume
normal cooling operation.
2
3
When installing, use the nearest power outlet. Make sure the power outlet is easy
to reach so you can quickly disconnect your air conditioner in case of emergency.
Ensure that the air conditioner is well supported, securely fastened, easily reachable
and not obstructed.
Aviod location with: salty or sulphurous air, draughts, dampness and flammable gas.
If you install the drainage system, be sure to channel the concensed water to a
suitable location.
Covers, obstructions and unsteady support may cause excessive operating noise and vibration.
The rear end of the air conditioner is splash proof. You don’t need to shield or cover it.
R32 refrigerant air conditioner installation and maintenance should be done by competent person.
There should not be any obstacles surrounding
the unit.
Prepare and installation hole slightly bigger than the
cabinet size.
Left and right side of the unit should be at least
15 cm away from the wall.
The minimum installation height is 75cm.
Dimension
Proposed to use 1/8” x 1-1/4” angle-
aluminium for installation frame and
side supporting bar.
1
Remove the front grille.
3
a
b
c
d
Remove the air filter.
Tilt up and pull out the air filter by the holder.
2
Air Inlet Louver
Cabinet
Front Grille
Air Filter
(behind the front intake grille)
Front Intake Grille
Vertical airflow direction vane
(Airflow direction adjustment up-down)
The vertical airflow direction vane is
controlled by positioning the vent to
discharge the air upwards, downwards,
or straight out.
The appliance shall be stored in a room without continuously operating ignition sources
(for example: open flames, an operating gas appliance or an operating electric heater)
Do not install, remove and reinstall the unit yourself.
Improper installation may cause Leakage, electric shock or fire. Please engage an authorized dealer
or specialist for the installation work.
Do not add or replace refrigerant other than the specified type.
It may cause product damage, burst and injury. If the supply cord is damaged, it must be replaced by
the manufacturer, its service agent or similar qualified persons in order to avoid hazard.
The room air conditioner must be earthed.
Improper grounding could cause electric shock.
Do not install the unit in a place where there are explosive gas leaks.
Gas leaks near the unit could cause fire.
Ensure that the drainage piping is connected properly.
R32
Otherwise water will leak out.
In cases that require mechanical ventilation, ventilation openings shall be kept clear of obstruction.
Ventilate any enclosed areas when installing or testing the refrigeration system.
Escaped refrigerant gas, on contact with fire or heat, can produce dangerously toxic gas.
Confirm after installation that no refrigerant gas is leaking. If the gas comes in contact with a burning
stove, gas water heater, electric room heater or other heat source, it can cause the generation of toxic gas.
INSTALLATION PRECAUTION
SAFETY PRECAUTIONS
1
Please observe these following safety precautions when using your air conditioner.
Failure or negligence in observing these safety precautions could cause fire, electrical shock or personal injury.
This sign warns of risk of
death or serious injury.
This symbol (with a white background) denotes an action that is
PROHIBITED.
These symbols (with a green background) denote actions
that are COMPULSORY.
Risk of fire /
Flammable
materials
This sign warns of risk of
injury or damage to property.
This symbol shows that this equipment uses a flammable refrigerant.
If the refrigerant is leaked, together with an external ignition source,there is a possibility of ignition.
This symbol shows that the Operating Instructions should be read carefully.
This symbol shows that service personnel should be handling this equipment with reference to the
Technical Manual.
This symbol shows that there is information included in the Operating Instructions and/or
Installation Instructions.
Before operating the unit, read these operating instructions thoroughly and keep them for future reference.
Open the Intake Griille until over 90°
front grille fulcrum can remove from Grille force arm.
Remove the screw on the front grille.
At the bottom right side of the front grille,
press inward on the cabinet near the power
cord, and pull the grille outward to the right
until right tab releases.
At the bottom left side, push inward on the
cabinet and pull the grille outward to the left
to release the left tab. Do not pull the bottom
edge towards to you for more than 3 inches to
prevent the two top tabs from damage.
Slide the front grille upwards to loosen the two
top tabs from slots at the top of the cabinet.
Front Grille Fulcrum
Body Support
Grille Force arm
air filter
OPERATION CONDITIONS
Use the air conditioner
under the following
conditions:
Operating temperature range.
Continuous operation at over 90% high humidity
may create condensation and result in
waterdrops on the intake and outlet vanes.
Max. Temperature
Min. Temperature
NOTE:
Humidity may exceed 90%
32
Indoor side
23
21
15
D.B.T.: Dry Bulb Temperature
(unit in °C)
D.B.T.
W.B.T.
W.B.T.: Wet Bulb Temperature
43
Outdoor side
26
21
15
D.B.T.
W.B.T.
ŶAvoid installation in the following locations.
ƔMechanical processing plants and other places with a lot of mechanical oil.
ƔHigh humidity areas such as laundry room and bathroom.
ŶAir conditioner normal operating temperature.
ƔIn side maximum temperature 30
℃
ƔOut side maximum temperature 43
℃
ŶNOTICE:
When the air conditioner is used at room temperature of 21 degrees or less,
the temperature may be too low, and the air conditioner may be easily
frosted. After frosting, it may be difficult to drain and may flow into the room.
(Based on IEC 60335-2-40, there is no restriction for the
minimum installation floor area since the refrigerant charges
is less than 1.224kg.
Ventilation Lever
The ventilation lever must be in CLOSE
position in order to maintain the best
cooling conditions.
When fresh air is necessary in the room, set
the ventilation lever to the Open position.
The damper is opened and room air is
drawn out.(If the ventilation lever is OPEN, there
is a chance that noisy noise can be introduced
into the room)
outdoor
CEILING
WALL
Over 15cm
Over 15cm
34.6cm
45cm
64cm
Fence
or likewise
Less than 24cm
indoor
outdoor
Over 100cm