background image

5. DESCRIPTION OF NIGHT LIGHT &PROGRAM MEMORY

* The night light is always on show blue light as default.
* When dispensing hot water the night light will turn red color.
* When dispensing cold water the night light will turn blue color.
* When dispensing ambient water the night light will turn red and blue both.
*When the machine is powered off, all settings data could be save for one week long,
otherwise you need re-setting.
*Any buttons are touched, the buzzer will be activated, and the sound with a chord
voice.

6. MACHINE FIRST TIME USE ATTENTIONS

1) Before power on,  Pis check whether the input water pipeline is well connected?

Make sure the heating switch on the back is on OFF(0) status.

[ Note ON--(1) side, OFF -(0) side] 

500ML 

S00ML·UV 

180ML 

180Ml 

2) Connect the plug to the power supply, start to dispense hot or cold water first.

))) 

))) 

*Hot water:  Keep press 

or 

CJ)

2 seconds wait till see the water come out from the

outlet nozzle  (Default hot water child lock function is on, so you need press 2S to

dispense hot water )
*Cold water:  Press 

(iJ 

or 

@

wait till see water come out from the outlet nozzle. 3) 

Turn on the heating switch at the back of the machine to start the heating function.

7.  Dry heating protection alarm and Compressor protection function 
program. 

1 )When the heating element sensor detects there is a dry heating, system will stop 

heating, and you will see both 

))} 

and 

· c0I'½ 

Y+ 

button keep flashing,The dry

- 07  -

Содержание HCM-T7

Страница 1: ...We would like you to utilize all the features of our device which equipped with internal smart filtration system Now you can enjoy an unlimited supply of high quality healthy tasty water just the way...

Страница 2: ......

Страница 3: ......

Страница 4: ...and the light turn from white to red the machine began to dispense hot water big cup till it finish the light will turn back white You can press any button to stop in advance as well 2 CJ Hot water s...

Страница 5: ......

Страница 6: ...aximum decrease 1 degree you can skip this step by press to exit the setting status Attention Anytime when customer active the temp setting status the hot and extra hot temp data will automatically re...

Страница 7: ...gether for 5 seconds The buzzer sounded and filter life is reset 5 Filter Replacement guideline and functionality instruction Step 1 Take out the filter cover Step 2 Take out and turn on the filter as...

Страница 8: ...ine is well connected Make sure the heating switch on the back is on OFF 0 status Note ON 1 side OFF 0 side 0 500ML S00ML UV 0 180ML 180Ml 2 Connect the plug to the power supply start to dispense hot...

Страница 9: ...int and compressor starts work again if the temp does not reach the cooling start temp point after 4 minutes the compressor protection function ends MACHINE WORKING PRINCIPLE Touch Display Card Night...

Страница 10: ...4 96 C 1st Sediment Activated carbon 1st Lifespan 3000L 550GAL 4 Block composite 2 UF Membrane ACF 5 Applicable water pressure 6 Rate Pure water Flow Water pressure 0 1 0 4Mpa 7 Applicable water Produ...

Страница 11: ......

Страница 12: ...contact the local service agency to replace the filter Inspect the connector to connect the pipe properly Replace the water pipe and PE pipe Use a three pin socket with earth wire making the machine...

Отзывы: