background image

USTIP

Quick Installation and Setup Guide

For more detailed instructions, please consult the User Guide found on the enclosed CD-ROM or visit www.raritan.com      Rev. D   April 2006  255-31-0007

1.

Attach the included AC power

cord to USTIP and plug the
other end into a nearby AC
power outlet.

2.

Connect the client PC to the

USTIP ADMIN Port using a seri-
al (DB9) cable. 

3.

Connect a standard Ethernet

cable from the Network Port to
an Ethernet switch, hub, or
router.

4.

On a USTIP1 unit, connect

the single Paragon port to the
User port on your UMT unit

using a CAT5 cable. On a
USTIP2 unit, connect both the
upper and the lower Paragon
ports to User ports on your UMT
unit using CAT5 cables. The
upper Paragon port allows you
to download the Paragon data-
base to the USTIP unit, and the
lower Paragon port allows local
access to the Paragon unit.

5.

Launch a Hyperterminal ses-

sion from the client PC. To
access the Serial Admin Port,
use  HyperTerminal to configure

specific settings with the follow-
ing steps:

A.

In Windows, click on the

Start > Programs > Accessories
>  Communications, and then
click HyperTerminal to start a
session.

B.

Name the HyperTerminal

session, select a session icon - if
required - and then click OK.

C.

In the Connect To window,

click on the Connect Using drop-
down arrow and select COM1
(or other option, depending on

where your PC's serial cable is connected)
and click OK.

D.

In the COM1 Properties window, click

on the 

Port Settings 

tab. Make sure the

Bits per second 

drop-down is 

115200 

and

Flow control 

drop-down is set to 

NONE,

and click 

OK.

E.

On the 

File

menu, click 

Properties;

click on the 

Settings 

tab, then click on the

Emulation

drop-down arrow and select

VT100.

i.

Click 

ASCII Setup 

and ensure that

the checkbox before 

Wrap lines that

exceed terminal width 

is checked and that

this is the only checkbox enabled on this
screen.

ii.

Click 

OK.

iii.

Click 

Terminal Setup 

and ensure

that the checkbox before 

Keypad applica-

tion mode 

is checked.

iv.

Click 

OK.

6.

Power ON USTIP.

7.

After booting, the USTIP Setup Wizard

appears on the Admin Console screen.

Press the letter 

on the Admin Console

keyboard to configure USTIP. 

8.

Navigate to the Network Configuration

Screen, assign a unique name to the
USTIP

unit, such as its location

(“ServerRoom”), and type its IP Address
parameters. Press 

CTRL+S 

to save the

data. 

9.

When the Main Menu appears, browse

through the Admin Console options to con-
figure USTIP for your environment. Please

see Raritan’s USTIP User Guide on the
enclosed CDROM for detailed instructions
on USTIP Configuration.

10.

When you are finished configuring the

USTIP unit, return to the Main Menu. Press
the letter 

and then press 

ENTER 

to

restart the USTIP and save your changes. 

11.

Press the letter 

and then press

ENTER 

to shut the USTIP down, and phys-

ically power OFF the unit. 

II. Attach Local Console for Initial Configuration

I. Prepare Servers and Network for Remote Operation

Congratulations on your purchase of USTIP, the industry-leading solution for multi-platform, high-perform-
ance, network-based, remote KVM console access. USTIP enables highly-secure, multi-user, bandwidth-
efficient, and software-independent access to your servers' KVM consoles via a web browser. USTIP uses
Raritan's powerful frame-grabber and Video Compression Algorithm to capture, digitize, and compress the
video signal before transmitting to a remote PC. The remote user has direct access and total control of tar-
get servers for maintenance, administration, and trouble-shooting, from running GUI applications to BIOS-
level troubleshooting, and even rebooting.

All Servers

A.

For optimal bandwidth effi-

ciency and video performance,
set the desktop background to a
predominantly solid, plain, light-
colored graphic.

B.

Ensure that the server’s

video resolution and refresh rate
are supported by USTIP, and
the signal is non-interlaced:

Text Modes:

640x480 @ 60Hz

1024x768 @ 60Hz

640x480 @ 72Hz

1024x768 @ 70Hz

640x480 @ 75Hz

1024x768 @ 75Hz

640x480 @ 85Hz

1024x768 @ 85Hz

720x400 @ 70Hz

1152x864 @ 60Hz

720x400 @ 85Hz

1152x864 @ 70Hz

800x600 @ 56Hz

1152x864 @ 75Hz

800x600 @ 60Hz

1280x960 @ 60Hz

800x600 @ 72Hz

1280x1024 @ 60Hz

800x600 @ 75Hz
800x600 @ 85Hz

Windows XP

Disable 

Enhanced Pointer

Precision 

and set the mouse motion
speed exactly to the middle
speed setting; these options are

located in Control Panel >
Mouse > Mouse Pointers.

Windows 2000 / ME

Set mouse pointer acceleration
to 

none

, and the mouse motion

speed to the middle speed set-
ting.

Windows 95 / 98 / NT

Set mouse motion speed to the
slowest setting in Control Panel
> Mouse > Motion.

Linux

Set mouse acceleration to
exactly 1, and threshold to
exactly 1.

Sun Solaris

Set mouse acceleration to
exactly 1.0. Ensure that your
video card is set to a supported
resolution, and is outputting
VGA (H-and-V Sync, not com-
posite sync). This non-default

configuration can be set in the
bootprom mode by issuing the
command

setenv output-device screen
:r1024x768x70

followed by the command 

boot

to reboot.

Macintosh

No specific mouse settings are
required when using USTIP to
access and control a Macintosh
system, but you must set the
USTIP client to 

single cursor

mode. 

Network / Firewall

To enable USTIP, your network
and firewall must allow commu-
nication on TCP Port 5000. 
Alternatively, USTIP can be con-
figured to use a different TCP
port of your own designation (in
step II-6 below).

1

2

Local Port

keyboard and mouse used to 

perform initial configuration

To AC Power Outlet

UST-IP1/2

5

4

3

6

III. Connect Remotely Using MPC or RRC

When you complete the physical installation of your USTIP unit, access Raritan Multi-Client Platform or Raritan Remote Client and estab-
lish an initial network connection. Raritan Multi-Platform Client (MPC) and Raritan Remote Client (RRC) are graphical interfaces that allow
you to remotely access the target devices connected to Raritan's Dominion, IP-Reach, and USTIP units.

Note: Please see the Raritan Multi-Platform Client and Raritan Remote Client User Guide, available on Raritan's Website http://www.rari-
tan.com/support/sup_prdmanuals.aspx, or on the Raritan User Manuals & Quick Setup Guides CD ROM, included with this shipment, for
details on installing and operating MPC and RRC. 

Launch MPC

To launch MPC from a Windows PC running
Internet Explorer, type 

http://<IP

address>/mpc 

into the IE address line.

Please note that the MPC applet will launch
in a new window that does not contain the IE
Menu bar, Tool bar, Scroll bar, or Address
bar. You can work in this window and toggle
to other open windows using the command

ALT+TAB 

when in a Windows environment.

You can also install MPC as a standalone
applet, described further in the Raritan Multi-
Platform Client and Raritan Remote Client
User Guide.
To launch MPC from any browser except
Internet Explorer running on a Windows PC,
type 

http://<IP address> 

into your browser's

address line, where <IP address> is the IP
address of the Raritan device.

Note: You must disable any pop-up blockers
in order to launch MPC.

Launch RRC
1.

Log on to any Windows-based comput-

er with network access to your Raritan
devices.

2.

If you are using Windows NT, 2000, XP,

or 2003, ensure that you are not a "restrict-
ed" user.

3.

Launch Microsoft Internet Explorer

(ensure that your Internet Explorer security
settings allow the download and execution
of ActiveX controls).

Note: A Windows default security setting of
Medium is sufficient.

4.

In the URL text field of your Web brows-

er, type the IP address you assigned earlier
in Step II-8. Press 

ENTER.

5.

After RRC launches, a device tree of all

automatically detected Raritan devices
found on your subnet is displayed on the left
side of the screen. If you do not find your
Raritan unit listed by name, create an icon
manually by selecting 

New Profile 

on the

Connection 

menu. 

6

Double-click on the icon that corre-

sponds to your Raritan unit.

Note:  RRC works only with MS Internet
Explorer. If you are using a different Web
browser, MPC will load automatically.

Отзывы: