36 D
OMINION
SX
I
NSTALLATION AND
O
PERATIONS
M
ANUAL
Network
Overview
The Network configuration screen provides an area for Administrators to define both the network and
modem (optional) settings for the unit.
Figure 40 Sample of Network Configuration Display
Some Dominion SX units come equipped with a 56Kbps (Kilobits per second) modem, which allows dial-
in access to the unit from virtually any location in the world. On other Dominion SX units, there is a
connector on the rear panel for a user-supplied external modem. Client computers connect to the unit by
establishing a PPP (Point-to-Point Protocol) link between the client machine and the Dominion SX unit.
Once the PPP connection is established, the client computer is physically on the same network as the
Dominion SX unit and can access the unit using Internet Explorer or Netscape browsers.
There are three requirements for dialing into the unit:
1.
The phone line to the unit must be connected.
2.
The modem / PPP connection settings must be configured.
3.
If modem Dial Back is enabled, type a valid phone number to ensure successful modem callback
connection. Type phone numbers from the command line interface (CLI) (under
Modem
) using SSH
(or telnet if enabled). Phone number entries can contain numbers, hyphens, and spaces.
4.
The dial-up networking software on the user’s personal computer must be configured to establish a
PPP connection from the client computer to the unit.
Configure Network Parameters
•
IP address
: IP address for the unit
•
IP subnet mask
: Subnet mask to be used when deployed in the network
•
IP gateway
: Gateway that the unit uses to communicate with other systems that are not on the same
subnet
•
Dominion SX Unit Name
: Name to be associated with the unit, 64 characters in length. Valid
characters are A-Z, a-z, -, _, 0-9, no spaces or special characters allowed
•
Terminal Type
: Type of terminal supported; default is VT100
•
Port Address
: Port address to be used by the unit when communicating with other systems; the default
port address is 51000, but can also be set to any value in the range of 1024-65536 (please verify this
value with your firewall administrator)
•
Domain name:
For example
mycompany.com
; domain name is required to send SMTP messages by
certain mail servers. Unless you the mail server used in your company does NOT require this
information to send email, it is safe to fill in this information. Most mail servers will require this
information.
•
Port address for CC management
: Port address is required for use by CommandCenter-SG (CC) to
discover Dominion SX units in the network. Default value is 5000; this value should NOT be changed
unless instructed to do so by the CC administrator. It is possible that other devices connected to the
Содержание SX32
Страница 2: ...This page intentionally left blank ...
Страница 4: ...This page intentionally left blank ...
Страница 78: ...68 DOMINION SX INSTALLATION AND OPERATIONS MANUAL ...
Страница 90: ...80 DOMINION SX INSTALLATION AND OPERATIONS MANUAL ...
Страница 94: ...84 DOMINION SX INSTALLATION AND OPERATIONS MANUAL ...
Страница 102: ...92 DOMINION SX INSTALLATION AND OPERATIONS MANUAL ...
Страница 106: ...96 DOMINION SX INSTALLATION AND OPERATIONS MANUAL ...
Страница 108: ...98 DOMINION SX INSTALLATION AND OPERATIONS MANUAL ...
Страница 122: ...112 DOMINION SX INSTALLATION AND OPERATIONS MANUAL ...
Страница 134: ...124 DOMINION SX INSTALLATION AND OPERATIONS MANUAL ...
Страница 174: ...164 DOMINION SX INSTALLATION AND OPERATIONS MANUAL ...
Страница 177: ...APPENDIX J TECHNICAL FAQS 167 ...
Страница 178: ...168 DOMINION SX INSTALLATION AND OPERATIONS MANUAL 255 60 2000 ...