CC-SG V1 Quick Setup Guide 

QSG-CCV1-0U-v7.0-E 

 255-80-5110-01-RoHS 

 
 
 

 
 

 

CommandCenter Secure Gateway V1 Models 

Thank you for your purchase of the CommandCenter Secure Gateway

, Raritan's management software platform 

engineered to consolidate secure access and control of IT devices. This Quick Setup Guide explains how to install and 
configure the CommandCenter Secure Gateway.   
For details on using the CommandCenter Secure Gateway, access online help from the application or the 

Support page

 

http://www.raritan.com/support

 on the Raritan website. Online help is your primary resource but a PDF version of the 

help is also available on the Support page.   

 

 

1

 

Power 

2

 

USB Ports 

3

 

LAN 1 

4

 

LAN 2 

5

 

KVM Port 

 

 

I. Unpack CC-SG 

With your shipment, you should receive:   
(1) CommandCenter Secure Gateway V1 unit 
(1) CommandCenter Secure Gateway V1 front bezel 
(1) Rack mount kit 
(1) Power supply cord 
(1) CAT 5 network cable   
(1) Printed Quick Setup Guide 
(1) Registration and Warranty papers 

 

Determine Rack Location 

Decide on a location in the rack for CC-SG, in a clean, 
dust-free, well-ventilated area. Avoid areas where heat, 
electrical noise, and electromagnetic fields are generated and 
place it near a grounded power outlet. 

 

QS Rule 

 

II. Rack-mount CC-SG 

 

Identify Rail Sections 

Your rack mount kit contains two rack rail assemblies. Each 
assembly has two sections: an inner fixed chassis rail (A) that 
secures to the unit and an outer fixed rack rail (B) that 

secures to the rail brackets. A sliding rail guide sandwiched 
between the two should remain attached to the outer fixed 
rack rail. The A and B rails must be detached from each other 
for installation. 

To remove the inner fixed chassis rail (A), pull it out as far as 
possible until you hear a clicking sound when a locking tab 
emerges from inside the rail assembly and locks the inner 
rail. Depress the locking tab to pull the inner rail completely 
out. Do this for both rack rail assemblies. 

 

Install the Chassis Rails 

1.

 

Position the inner fixed chassis rail sections you just 

removed along one side of the chassis; ensure the five 
screw holes line up.   

2.

 

Screw the rail securely to the side of the chassis. 

3.

 

Repeat steps 1 and 2 for the other rail on the other side of 
the chassis. Attach rail brackets if installing into a Telco 
rack. 

 

Install Rack Rails 

1.

 

Position the outer fixed rack rail/sliding rail guide 

assemblies at the desired location in the rack, keeping the 
sliding rail guide facing the inside of the rack. 

2.

 

Screw the assembly securely to the rack using the 
brackets provided. 

3.

 

Attach the other assembly to the other side of the rack, 

making sure that both are at the exact same height and 
with the rail guides facing inward. Ideally, two people 
should work on this together. 

 

Install CC-SG into the Rack 

Once the rails are attached to both the chassis and the rack, 
install CC-SG into the rack. 

 