Figure 4-21
Date/Time Properties
4. Adjust the
Date, Current Time, and/or Time Zone.
NOTE:
Drag the blue header bar over to the left to display the right side of the screen.
5. Press Apply.
6. Press OK.
Calibrate Flows
Step by step instruction is taught during the hands-on training class. This function should not be performed
without a full understanding of what is being changed as it can render the device inoperable. It may resolve a
warning but could also be masking another problem.
1. Select Menu > Advanced Menu > Page 2.
2. Press Calibrate Flows.
A message displays verifying you want to calibrate flows.
3. Press Yes.
Figure 4-22
Flow Calibration
4. Modify the fields, as necessary.
CHAPTER 4 │User's Guide
67
Rapiscan Systems Proprietary and Confidential