7. Operation
Skilled staff may only carry out all work.
Impurities have tobe removed immediately according to local regulations.
Before operating the GTK device check it for leaks and defects and if necessary
repair.
In times out of work the system must be depressurized to prevent damages and
accidents.
7.1 Connect to air supply. Open the ball cock of compressed of pneum.
maintenance unit. The pumps start operating.
7.2 Put the bin which shall be filled under the spigot chosen of oil bar
7.3 Operate the tap to get out the oil
7.4 Once the desired amount is reached, return the tap to its original position to
complete the tapping process
7.5 Close the ball cock of pneum. maintenance unit and cut off the air supply.
8. Maintanence and trouble shooting
Check the device from time to time for leaks, damages and impurities and if
necessary remove and repair, in order to prevent damages and accidents.
Skilled staff may only carry out repairs.
Problem
Reason
Solution
No air supply
Connect to air supply
Flexible air hose defect
Replace hose
Ball cock closed at air supply
Open ball cock
Pump is colgged
Clean the pump
Pump is defect
Contact manufacturer
Suction hose clogged
Clean suction hose
Pressure reducer defect
Replace pressure reducer
Pump does draw air
Check for leaks and if necessary
repair
Pump does not run
Check pump - refer to above
mentioned
Spigot jammed
Repair spigot
Spigot clogged
Clean spigot
Barrel is empty
Replace barrel
Suction hose not deep enough
inserted
Put suction hose deeply into the
medium
Suction hose defect
Repair suction hose
Connections are leaking
Seal in again the connections
Pump does not
run
Pump does not
supply
Oilbar does
supply no or onls
little oil
Oil bar draw s air
10