Operating Instructions D50+ | P50+ | SHERAprint 50
Rapid Shape GmbH
│
DOCR000438
60
│
96
7.9.4
Automatic Refill: Re-Pumping Printing Material Manually
NOTE!
Wearing protective gloves protects the skin from contact
with skin damaging materials. During work steps in
which you work with printing materials or cleaning
agents, we always recommend wearing protective
gloves.
Material can be pumped into the reservoir manually to check the
“Automatic Refill” function. The following requirements must be met for
this:
–
The “Automatic Refill” function is enabled, and a hose is
connected between the material bottle and the material
reservoir.
→
Chapter 7.9.2
–
A reservoir with a low filling level (< 50%) is inserted.
Re-Pumping Printing Material Manually
1.
In the main menu: press the
«
Manual Mode
»
button.
2.
Press the
«
Manual Refill
»
button in “Manual Mode” to open the
“Manual Refill” overview.
3.
Enabling Auto Pump: Press the
«
Auto On
»
button to enable the
pumping process.
Since the filling level in the inserted reservoir
is too low (< 50%), the pumping process starts immediately,
and material is pumped in. Pumping stops as soon as the
reservoir is full.
4.
Disabling Auto Pump: Press the
«
Auto Off
»
button to switch the
function off again.
5.
Return to the main menu.
Figure 28: Manual mode,
”Manual Refill“
overview
The
«
Auto On
»
&
«
Auto Off
»
buttons have no influence
over the refill logic during the printing process and are
only used to check the “Automatic Refill” function in
manual mode.