Operating Instructions D50+ | P50+ | SHERAprint 50
Rapid Shape GmbH
│
DOCR000438
42
│
96
7.5.10
Move Jobs in Queue on complete
When using a job queue with several print jobs, you can set each print
job in a queue to be automatically moved to the “Completed Folder”
following completion (Main Menu >
«
More Functions
»
>
«
File
Management
»
>
«
Switch Folder
»
). The jobs can then be further
administered there. This function can be set with the button
«
Move jobs
in queue on complete
»
.
Proceed as follows to set this function:
1.
Access the
«
Customer
»
menu: Main Menu >
«
Setup
»
>
«
Service
»
>
«
Switch Level
»
>
«
Customer
»
.
2.
Locate the button
«
Move jobs in queue on complete
»
in the
centre of the display.
The button lights up red when the function
is disabled.
3.
Press the button next to the description to enable the function.
The button lights up green when the function is enabled.
4.
Press the
«
Save
»
button on the right-hand side of the display to
save the setting.
5.
Return to the main menu.
7.5.11
Maximum Jobs in Basket
The Automatic Separation Function (ASM function) makes the
separated printed parts fall into a collection basket to be removed from
the machine. Thereby, you can set the number of print jobs that can be
collected in the collection basket until the basket needs to be emptied.
The number of print jobs can be set with the
«
Maximum jobs in basket
»
input field.
To enter the number of print jobs, refer to the separate chapter
Up & Administrating the Automatic Separation Function
→
Chapter 7.7
7.5.12
Offset Part Detection
The
“
Offset part detection
”
function enables fine adjustment of part
detection by the build platform in the material reservoir during the
printing process. A higher offset results in component recognition with
a higher tolerance range, whereas a smaller offset means that the
component recognition is to be very fine and can lead to faulty print
jobs under certain circumstances. This function can be set in the
«
Offset part detection
»
input field.
Proceed as follows to set this function:
1.
Access the
«
Customer
»
menu: Main Menu >
«
Setup
»
>
«
Service
»
>
«
Switch Level
»
>
«
Customer
»
.
2.
Locate the input field
«
Offset part detection
»
in the centre of the
display.
3.
To change the offset value, access the Windows keyboard on
the touch display by swiping upwards from the bottom edge of
the display.
4.
Set your chosen offset value.
5.
Press the
«
Save
»
button on the right-hand side of the display to
save the setting.
6.
Return to the main menu.