Dual-Plane Self-Calibration Procedure
The Dual-Plane Self-Calibration Procedure ensures the Balancer is producing accurate readings by
aligning the software with the existing spindle positions and hardware on the Balancer.
Before performing the Dual-Plane Self-Calibration Procedure, ma
ke
sure the Balancer is anchored to
the floor and that the shaft and centering cones are clean and undamaged. Dirt or damage can cause
inaccurate readings.
Important
:
Pay close attention to this procedure. If not done correctly, the Balancer will not
produce accurate readings, leading to Wheels not being balanced correctly.
You will need a steel Wheel with a Tire of a commonly balanced size for this procedure. The Wheel
must already be fully balanced.
To perform the Dual-Plane Self-Calibration Procedure
:
1.
Mount an already balanced Wheel on the Balancer.
2.
Enter the correct Distance, Width, and Diameter values for the Wheel into the Balancer.
3.
Press and hold
Start
and
R
until
CAL | CAL
appears on the Inner and Outer Windows and the
Indicators under those windows stop flashing.
4.
Lower the Hood to start a balancing session.
The Wheel spins briefly, then stops.
3.50
appears in the Inner Window (
100
if grams are selected) and
Add
appears in the Outer
Window.
5.
Turn the Wheel by hand until the Indicators under the Inner Window are all lit.
6.
Add a 3.5 ounce /100 gram Calibration Weight (it’s a Clip-On Weight) to the Inner Edge of the
Wheel at Top Dead Center (12 o’clock high).
7.
Close the Hood to start a balancing session.
The Wheel spins briefly, then stops.
Add
appears in the Inner Window and
3.50
appears in the Outer Window (
100
if grams are
selected) and.
8.
Turn the Wheel by hand until the Indicators under the Outer Window are all lit.
9.
Remove the Calibration Weight from the Inner Edge of the Wheel and add it to the
Outer Edge at
Top Dead Center (12 o’clock high).
10.
Close the Hood to start a balancing session.
The Wheel spins briefly, then stops.
End
appears on the Inner Window and
CAL
appears on the Outer Window.
11.
Remove the Calibration Weight from the Wheel.
The Dual-Plane Self-Calibration Procedure is complete.
Important
:
If the Dual-Plane Self-Calibration Procedure does not complete successfully, visit
, call
BendPak Ranger at (805) 933-9970
,
Содержание DST30P
Страница 44: ...DST30P Wheel Balancer 44 P N 5900163 Rev C1 March 2020 Labels ...
Страница 45: ...DST30P Wheel Balancer 45 P N 5900163 Rev C1 March 2020 ...
Страница 46: ...DST30P Wheel Balancer 46 P N 5900163 Rev C1 March 2020 Parts Main Cabinet ...
Страница 49: ...DST30P Wheel Balancer 49 P N 5900163 Rev C1 March 2020 Hood Mounting Assembly ...
Страница 52: ...DST30P Wheel Balancer 52 P N 5900163 Rev C1 March 2020 Brake Assembly ...
Страница 54: ...DST30P Wheel Balancer 54 P N 5900163 Rev C1 March 2020 Accessories ...
Страница 56: ...DST30P Wheel Balancer 56 P N 5900163 Rev C1 March 2020 Display Panel ...
Страница 58: ...DST30P Wheel Balancer 58 P N 5900163 Rev C1 March 2020 Maintenance Log ...
Страница 59: ...DST30P Wheel Balancer 59 P N 5900163 Rev C1 March 2020 Maintenance Log ...
Страница 60: ...1645 Lemonwood Drive Santa Paula CA 93060 USA 2020 BendPak Inc All rights reserved bendpak com ...