VNA GUI reference
R&S
®
ZNL/ZNLE
559
User Manual 1178.5966.02 ─ 19
Remote command:
MMEMory:LOAD:VNETworks<Ch>:GLOop:DEEMbedding
MMEMory:LOAD:VNETworks<Ch>:GLOop:EMBedding
Set to Ideal Ground
This function is enabled as long as the 1-Port Data network is active. An imported S-
parameter set is replaced by the S-parameters of an ideal through connection, which
eliminates the transformation network.
10.14.8
Differential Match tab
Allows you to specify a 2-port embedding network for the differential mode of a bal-
anced port.
Such a network is either defined
●
via its S-parameter stored in a two-port Touchstone file (
*.s2p
) or
●
by specifying the parameters of a "Shunt L, Shunt C" lumped element model
Use the complementary dock widget to access the balanced port configuration and to
activate or deactivate "Differential Match" embedding for selected balanced ports (see
Chapter 10.14.1.8, "Differential Match panel"
Background information
Refer to
Chapter 9.6.2.8, "Differential match embedding"
If the "Fixture Simulator" is disabled for the related channel (see
on page 527), this tab is inactive, i.e. all controls except the "Overview" button are
grayed out.
Offset Embed softtool