Remote Commands
R&S
®
ZNH
275
User Manual 1334.5985.02 ─ 02
Example:
CALC:TRAN:DTF:PEAK:RES2?
Reads out the second result in the DTF peak list.
Usage:
Query only
CALCulate<1...2>:TRANsform:DTFault:PEAK[:STATe]
<State>
This command turns the display of the DTF list on and off.
The numeric suffix at CALibration is irrelevant for this command.
Suffix:
<1...2>
.
1...2
Parameters:
<State>
ON | OFF
ON
DTF list turns on.
OFF
DTF list turns off.
Example:
CALC:TRAN:DTF:PEAK ON
Turns on the DTF peak list.
CALCulate<1...2>:TRANsform:DTFault:PEAK:THReshold
<Threshold>
This command defines the threshold for the DTF list.
All values that exceed the threshold are in the DTF list. You can query the list with
CALCulate<1...2>:TRANsform:DTFault:PEAK:DATA<1...10>?
The numeric suffix at CALibration is irrelevant for this command.
Suffix:
<1...2>
.
1...2
Parameters:
<Threshold>
The unit depends on the measurement format.
Example:
CALC:TRAN:DTF:PEAK:THR -20
Sets the threshold to -20 dB.
CALCulate<1...2>:MARKer<1...6>:FUNCtion:DTF:PEAK:THReshold
<ThresholdLevel>
This command queries the DTF list.
All values that exceed the threshold are in the DTF list. You can query the list with
CALCulate<1...2>:TRANsform:DTFault:PEAK:DATA<1...10>?
The numeric suffix at CALCulate and MARKer are irrelevant for this command.
Suffix:
<1...2>
.
1...2
Remote Control - Commands