Command Reference
R&S
®
ZNC
685
User Manual 1173.9557.02 ─ 13
CALCulate<Chn>:MARKer<Mk>:FUNCtion:DELTa:STATe
<Boolean>
Switches the delta mode for marker
<Mk>
on trace no.
<Chn>
on or off.
Note:
This command is the ZVR-compatible equivalent of
.
Suffix:
<Chn>
.
Channel number used to identify the active trace.
<Mk>
Marker number in the range 1 to 10.
Parameters:
<Boolean>
ON | OFF - enable or disable the delta mode.
*RST:
OFF
CALCulate<Chn>:MARKer<Mk>:FUNCtion:TARGet
<SearchValue>
Defines the target value for the target search of marker no.
<Mk>
, which can be activated
TARGet
.
Note:
This command is the ZVR-compatible equivalent of
.
Suffix:
<Chn>
.
Channel number used to identify the active trace.
<Mk>
Marker number in the range 1 to 10.
Parameters:
<SearchValue>
Target search value of marker no.
<Mk>
.
Range:
Depending on the format of the active trace. For a dB
Mag trace the range is -200 dB to +200 dB.
Increment: 0.1 dB
*RST:
Depending on the trace format; 0 dB for a dB Mag
trace.
Default unit: dB
CALCulate<Chn>:MARKer<Mk>:FUNCtion[:SELect]
<Mode>
Selects a search mode for marker no.
<Mk>
, which can then be initiated using one of the
CALCulate<Ch>:MARKer<Mk>:SEARch...
,
CALCulate<Ch>:MARKer<Mk>:MAXimum
or
CALCulate<Ch>:MARKer<Mk>:MINimum
functions. The marker must be created
before using
ON
.
Note:
This command is not needed except for compatibility with ZVR programs. Use
to select a search mode and
at the same time initiate the search. The
CALCulate<Ch>:MARKer<Mk>:SEARch...
,
CALCulate<Ch>:MARKer<Mk>:MAXimum
or
CALCulate<Ch>:MARKer<Mk>:MINimum
functions also select the search mode.
R&S ZVR/ZVAB Compatible Commands