Manual Operation
R&S
®
UPV
187
Getting Started 1146.2078.62 ─ 09
Data list settings
Function
Front panel
PC keyboard
Mouse
Open panel for configur-
ing a data list
Press the MENU key
and highlight the
"Disp Config" button with
the rotary knob or cursor
keys, open the pulldown
menu with the ENTER
key or a rotary knob click
and highlight the
selected corresponding
panel.
Press shortcut CTRL +
M, then highlight the
Disp Config button using
the TAB or SHIFT + TAB
keys, open the pulldown
menu using the Enter
key, highlight the desired
panel using the cursor
keys and select using
the Enter key.
Open the menu bar by
moving to the left edge
of the screen, activate
the Disp Config button
and click the desired
panel.
For an in-depth description with the detailed options for the settings in these panels,
see the operating manual on the documentation CD.
A number of basic settings for the data lists are described here using examples.
The measured values displayed in the lists are always linked to the values in the result
graphics. This means that all settings in the configuration panels, e.g. unit, engineer-
ing, set limits and so on, are also applied to the measured values in the lists.
The position of the cursor is also shown in the lists; the highlighted measurement num-
ber indicates the location of the cursor. Similarly, the step size of cursor movement set
via the softkey bar (see the previous section) also affects the movement of the cursor
in the data list.
There are three ways of navigating in the lists:
●
As soon as a value has been highlighted in the list (blue selection frame), it is pos-
sible to use the rotary knob to move from value to value within the column. The
cursor keys can also be used to move around in the lists.
The up/down cursor keys navigate in columns, the left/right keys in rows.
●
If an external PC keyboard is used, the keys TAB / CTRL + TAB can also be used
to move down/up within the column. Once again, the cursor keys UP and DOWN
are used to navigate through the columns and the cursor keys LEFT and RIGHT to
navigate through the rows.
●
If a mouse is used, you can either click the desired value or navigate using the
scrollbar.
As soon as the data list has the focus, softkeys appear at the bottom of the screen.
The "Close" button closes the data list.
If the "Find Cursor" button is activated, the displayed section of the data list changes
so that the value highlighted with the cursor is in the middle of the list. If both cursors
are activated, this button is used to toggle between the two cursor values.
Using the "Selection" button, it is possible to filter the list of displayed measured val-
ues, i.e. to list only selected rows. If this button is activated, a further softkey level
appears containing softkeys for selecting the displayed values:
Measurement Displays