Remote Control Commands
R&S
®
SMJ100A
803
Operating Manual 1403.7458.32 ─ 14
Example:
TEST:DIR 'SSYN',0,#H12345678
TEST:DIR? 'SSYN',0
Response:
#H12345678
7.20 TRIGger Subsystem
The
TRIGger
system contains the commands for selecting the trigger source for the
RF and LF sweep. The trigger input connectors are configured in the
SOURce:INPut
subsystem.
The trigger system of the R&S
SMJ is a simplified implementation of the SCPI trigger
system. The
TRIGger
system differs from the SCPI system as follows:
●
No
INITiate
command; the instrument behaves as if
INITiate:CONTinuous
ON
were set.
●
Under
TRIGger
several sweep subsystems exist.
Other commands associated with the trigger system of the R&S
SMJ can be found in
the modulation and RF signal subsystems.
TRIGger<hw>
●
Suffix
TRIGger<1|2>
is not permitted
●
TRIGger0
activates the LF output.
Table 7-3: Cross-reference between the manual and remote control
R&S name
SCPI name
Command under manual con-
trol
AUTO
IMMediate
"Auto" mode
SINGle
BUS
"Single" mode.
EXTernal
EXTernal
"Ext Single" and "Ext Step" mode.
Use command
LFO:SWEep:MODE
to select between the two sweep
modes.
EAUTo
-
"Ext Start/Stop" mode.
....................................................................................804
:TRIGger<hw>:FSWeep[:IMMediate]
................................................................................804
.............................................................................................. 805
.................................................................................805
:TRIGger<hw>:LFFSweep:IMMediate
.............................................................................. 806
....................................................................................806
:TRIGger<hw>:PSWeep[:IMMediate]
................................................................................807
....................................................................................807
:TRIGger<hw>[:SWEep][:IMMediate]
................................................................................808
............................................................................................. 809
TRIGger Subsystem
Содержание SMJ100A
Страница 34: ...Preface R S SMJ100A 18 Operating Manual 1403 7458 32 14 Notes on Screenshots...
Страница 86: ...Preparing for Use R S SMJ100A 70 Operating Manual 1403 7458 32 14 LXI Configuration...
Страница 139: ...Manual Operation R S SMJ100A 123 Operating Manual 1403 7458 32 14 Legend of Front Panel Controls...
Страница 140: ...Manual Operation R S SMJ100A 124 Operating Manual 1403 7458 32 14 Legend of Front Panel Controls...
Страница 454: ...Instrument Function R S SMJ100A 438 Operating Manual 1403 7458 32 14 Baseband Signal Baseband Block...
Страница 826: ...Remote Control Commands R S SMJ100A 810 Operating Manual 1403 7458 32 14 UNIT Subsystem...
Страница 828: ...Maintenance R S SMJ100A 812 Operating Manual 1403 7458 32 14 Storing and Packing...
Страница 843: ...Hardware Interfaces R S SMJ100A 827 Operating Manual 1403 7458 32 14 Figure A 2 BERT circuit diagram BERT Connector...
Страница 844: ...Hardware Interfaces R S SMJ100A 828 Operating Manual 1403 7458 32 14 BERT Connector...