Remote Control Commands
R&S
®
SMJ100A
709
Operating Manual 1403.7458.32 ─ 14
Return values:
<Value>
float
Range:
-100 to 100
Increment: 0.01
*RST:
0
Example:
CORR:VAL?
queries the value currently used for level correction.
Response:
-3
the correction value is - 3 dB.
Usage:
Query only
Manual operation:
See
"User Correction Value - User Correction"
[:SOURce<hw>]:CORRection:ZERoing:STATe
<State>
Activates the zeroing procedure before filling the user correction data acquired y a sen-
sor.
Parameters:
<State>
0 | 1 | OFF | ON
Manual operation:
See
"Fill User Correction Data with Sensor"
7.16.5 SOURce:FM Subsystem
The FM subsystem contains the commands for checking the frequency modulation.
The settings for the internal modulation source (LF generator) are made in the
For information about the required options, see
Chapter 5.5.11.4, "Frequency Modula-
...................................................................................... 709
[:SOURce<hw>]:FM:EXTernal:COUPling
..........................................................................710
[:SOURce<hw>]:FM:INTernal:FREQuency
....................................................................... 710
.............................................................................................710
.....................................................................................711
..........................................................................................711
............................................................................................ 712
[:SOURce<hw>]:FM[:DEViation]
<Deviation>
Sets the deviation of the frequency modulation signal in Hz. The maximum deviation
depends on the set RF frequency and the selected modulation mode (see data sheet).
SOURce Subsystem
Содержание SMJ100A
Страница 34: ...Preface R S SMJ100A 18 Operating Manual 1403 7458 32 14 Notes on Screenshots...
Страница 86: ...Preparing for Use R S SMJ100A 70 Operating Manual 1403 7458 32 14 LXI Configuration...
Страница 139: ...Manual Operation R S SMJ100A 123 Operating Manual 1403 7458 32 14 Legend of Front Panel Controls...
Страница 140: ...Manual Operation R S SMJ100A 124 Operating Manual 1403 7458 32 14 Legend of Front Panel Controls...
Страница 454: ...Instrument Function R S SMJ100A 438 Operating Manual 1403 7458 32 14 Baseband Signal Baseband Block...
Страница 826: ...Remote Control Commands R S SMJ100A 810 Operating Manual 1403 7458 32 14 UNIT Subsystem...
Страница 828: ...Maintenance R S SMJ100A 812 Operating Manual 1403 7458 32 14 Storing and Packing...
Страница 843: ...Hardware Interfaces R S SMJ100A 827 Operating Manual 1403 7458 32 14 Figure A 2 BERT circuit diagram BERT Connector...
Страница 844: ...Hardware Interfaces R S SMJ100A 828 Operating Manual 1403 7458 32 14 BERT Connector...