Remote Control Commands
R&S
®
SGT100A
463
User Manual 1176.8674.02 ─ 07
Parameters:
<Mode>
SINGle | DOUBle
SINGle
Enables single pulse generation.
DOUBle
Enables double pulse generation. The two pulses are generated
in one pulse period.
*RST:
SINGle
Example:
PULM:MODE DOUB
enables double pulse generation.
Manual operation:
See
[:SOURce<hw>]:PULM:PERiod
<Period>
Sets the period of the generated pulse. The period determines the repetition frequency
of the internal signal.
Example:
PULM:PER 220 us
the pulse period is 220 us.
Manual operation:
See
[:SOURce<hw>]:PULM:POLarity
<Polarity>
Parameters:
<Polarity>
NORMal | INVerted
NORMal
The RF signal is suppressed during the pulse pause.
INVerted
The RF signal is suppressed during the pulse.
*RST:
NORMal
Example:
PULM:POL INV
selects inverted polarity.
Manual operation:
See
[:SOURce<hw>]:PULM:SOURce
<Source>
Selects the source for pulse modulation.
SOURce Subsystem